Integrated Flexible Electronic Devices Based on Passive Alignment for Physiological Measurement.

Jin Hwa Ryu, Sangwon Byun, In-Bok Baek, Bong Kuk Lee, Won Ick Jang, Eun-Hye Jang, Ah-Yung Kim, Han Yung Yu

Abstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Jin Hwa RyuBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. gas96@etri.re.kr.
Sangwon ByunDepartment of Electronics Engineering, Incheon National University, Incheon 22012, Korea. ibbaek@etri.re.kr.
In-Bok BaekBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. bklee32@etri.re.kr.
Bong Kuk LeeBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. wijang@etri.re.kr.
Won Ick JangBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. cleta4u@etri.re.kr.
Eun-Hye JangBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. aykim@etri.re.kr.
Ah-Yung KimBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. swbyun@inu.ac.kr.
Han Yung YuBio-Medical IT Convergence Research Division, Electronics and Telecommunications Research Institute (ETRI), Daejeon 34129, Korea. uhan0@etri.re.kr.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This study proposes a simple method of fabricating flexible electronic devices using a metal template for passive alignment between chip components and an interconnect layer, which enabled efficient alignment with high accuracy. An electrocardiogram (ECG) sensor was fabricated using 20 µm thick polyimide (PI) film as a flexible substrate to demonstrate the feasibility of the proposed method. The interconnect layer was fabricated by a two-step photolithography process and evaporation. After applying solder paste, the metal template was placed on top of the interconnect layer. The metal template had rectangular holes at the same position as the chip components on the interconnect layer. Rectangular hole sizes were designed to account for alignment tolerance of the chips. Passive alignment was performed by simply inserting the components in the holes of the template, which resulted in accurate alignment with positional tolerance of less than 10 µm based on the structural design, suggesting that our method can efficiently perform chip mounting with precision. Furthermore, a fabricated flexible ECG sensor was easily attachable to the curved skin surface and able to measure ECG signals from a human subject. These results suggest that the proposed method can be used to fabricate epidermal sensors, which are mounted on the skin to measure various physiological signals.

Indexed as

Electronics, MedicalElectrocardiographyelectrocardiogram (ECG) sensorflexible electronic deviceinterconnectionpassive alignment

Identifiers

PMID28420219
PMCPMC5426539

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.