Evidence map›Paper›PMID 28418269›Full record

Trial reportActa orthopaedica2017

Is a hollow centralizer necessary when using a polished, tapered, cemented femoral stem?

Erik Weber, Christer Olsson, Uldis Kesteris, Gunnar Flivik

Abstract readRandomized Controlled Trial
In one paragraph

Trial report in Acta orthopaedica, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Review
  5. Femoral Stem Cementation in Hip Arthroplasty: The Know-How of a "Lost" Art.Current reviews in musculoskeletal medicine · 2021
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Erik Webera Department of Orthopedics , Skåne University Hospital, Clinical Sciences, Lund University , Lund.
Christer Olssonb Department of Orthopedics , Blekinge County Hospital , Karlshamn , Sweden.
Uldis Kesterisa Department of Orthopedics , Skåne University Hospital, Clinical Sciences, Lund University , Lund.
Gunnar Flivika Department of Orthopedics , Skåne University Hospital, Clinical Sciences, Lund University , Lund.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background and purpose - A tapered, polished and collarless stem is normally equipped with a hollow centralizer to prevent the stem from becoming end-bearing in the cement as the stem subsides. In a randomized clinical trial, we evaluated such a stem (MS-30), which was initially introduced with a solid centralizer but was later recommended to be fitted with a hollow centralizer. We hypothesized that while the stem would sink more, it would become rotationally stable and have less retroversion with a hollow centralizer than with a solid centralizer. Patients and methods - We randomized 60 patients with primary hip arthritis to receive either a hollow centralizer or a solid centralizer with the stem. The effect was evaluated over a 10-year follow-up period with repeated RSA examinations, conventional radiographs, and clinical follow-ups using the WOMAC and SF-12 questionnaires. Results - At 10-year follow-up, the group with hollow centralizers had subsided more than the group with solid centralizers (1.99 mm (hollow) as opposed to 0.57 mm (solid); p < 0.001). However, rotation was similar at 10-year follow-up (mean retroversion 1.34° (hollow) and 1.30° (solid)). Both groups showed excellent 10-year results, with similar clinical outcome, and none of the stems were radiographically loose or had been revised. Interpretation - As expected, there was more subsidence in the group with hollow centralizers, and with similar magnitude to that reported in earlier RSA studies on conceptually similar prostheses. Interestingly, there was no difference in the rotational behavior of the prostheses. This stem type appears to have a design that, regardless of the type of centralizer and the possibility of subsidence, withstands the rotational forces it is subjected to very well. This study does not support the need for a hollow centralizer for these types of stems.

Indexed as

Hip ProsthesisAgedAged, 80 and overArthroplasty, Replacement, HipFemaleHumansMaleMiddle AgedProsthesis DesignProsthesis FailureRange of Motion, Articular

Identifiers

PMID28418269
PMCPMC5499327

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.