Evidence map›Paper›PMID 28414927›Full record

ArticleComputerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society2017

Integration of free-hand 3D ultrasound and mobile C-arm cone-beam CT: Feasibility and characterization for real-time guidance of needle insertion.

E Marinetto, A Uneri, T De Silva, S Reaungamornrat, W Zbijewski, A Sisniega, S Vogt, G Kleinszig, J Pascau, J H Siewerdsen

Abstract read
In one paragraph

Article in Computerized medical imaging and graphics : the official journal of the Computerized Medical Imaging Society, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. 3D-XGuide: open-source X-ray navigation guidance system.International journal of computer assisted radiology and surgery · 2021
    Article
  5. Flexible needle and patient tracking using fractional scanning in interventional CT procedures.International journal of computer assisted radiology and surgery · 2019
    Article
  6. The more IGRT systems, the merrier?Journal of applied clinical medical physics · 2017
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

E MarinettoDepartmento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain; Department of Biomedical Engineering, Johns Hopkins University, MD, USA.
A UneriDepartment of Computer Science, Johns Hopkins University, Baltimore, USA.
T De SilvaDepartment of Biomedical Engineering, Johns Hopkins University, MD, USA.
S ReaungamornratDepartment of Computer Science, Johns Hopkins University, Baltimore, USA.
W ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, MD, USA.
A SisniegaDepartment of Biomedical Engineering, Johns Hopkins University, MD, USA.
S VogtSiemens Healthcare XP Division, Erlangen, Germany.
G KleinszigSiemens Healthcare XP Division, Erlangen, Germany.
J PascauDepartmento de Bioingeniería e Ingeniería Aeroespacial, Universidad Carlos III de Madrid, Instituto de Investigación Sanitaria Gregorio Marañón, Madrid, Spain.
J H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, MD, USA; Department of Computer Science, Johns Hopkins University, Baltimore, USA. Electronic address: jeff.siewerdsen@jhu.edu.

Funding

Intraoperative Imaging for Guidance, Patient Safety, and OR Quality AssuranceR01EB017226 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI SIEWERDSEN, JEFFREY H · 2014 to 2017
$2.1M
NIBIB NIH HHS R01 EB017226
6 · The paper itself

Abstract

This work presents development of an integrated ultrasound (US)-cone-beam CT (CBCT) system for image-guided needle interventions, combining a low-cost ultrasound system (Interson VC 7.5MHz, Pleasanton, CA) with a mobile C-arm for fluoroscopy and CBCT via use of a surgical tracker. Imaging performance of the ultrasound system was characterized in terms of depth-dependent contrast-to-noise ratio (CNR) and spatial resolution. US-CBCT system was evaluated in phantom studies simulating three needle-based procedures: drug delivery, tumor ablation, and lumbar puncture. Low-cost ultrasound provided flexibility but exhibited modest CNR and spatial resolution that is likely limited to fairly superficial applications within a ∼10cm depth of view. Needle tip localization demonstrated target registration error 2.1-3.0mm using fiducial-based registration.

Indexed as

NeedlesCone-Beam Computed TomographyFluoroscopyHumansImaging, Three-DimensionalPhantoms, ImagingUltrasonography, InterventionalC-arm imagingCone-beam CTImage-guided proceduresTarget registration errorUltrasound

Identifiers

PMID28414927
PMCPMC9097947

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.