Evidence map›Paper›PMID 28413682›Full record

ArticleJournal of therapeutic ultrasound2017

Multi-focal HIFU reduces cavitation in mild-hyperthermia.

Vandiver Chaplin, Charles F Caskey

Open access · hybridAbstract read
In one paragraph

Article in Journal of therapeutic ultrasound, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.9field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 18 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Multifocused Ultrasound Therapy for Controlled Microvascular Permeabilization and Improved Drug Delivery.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2021
    Article
  5. Article
  6. Focused Ultrasound for Immunomodulation of the Tumor Microenvironment.Journal of immunology (Baltimore, Md. : 1950) · 2020
    Review
  7. Article
  8. Article
  9. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Vandiver ChaplinVanderbilt University Institute of Imaging Science, 1161 21st Avenue South, Nashville, TN 37232 USA.ORCID 0000-0002-4074-0391
Charles F CaskeyVanderbilt University Institute of Imaging Science, 1161 21st Avenue South, Nashville, TN 37232 USA.
Vanderbilt University · US

Funding

Vanderbilt/Meharry Initiative for Minority Student DvptR25GM062459 · NIGMS · VANDERBILT UNIVERSITY · PI VELEZ EDWARDS, DIGNA R · 2002 to 2020
$10.4M
Institutional Predoctoral Training Program in Biomedical Imaging ScienceT32EB014841 · NIBIB · VANDERBILT UNIVERSITY · PI GORE, JOHN C · 2013 to 2017
$771k
NIBIB NIH HHS T32 EB014841NIGMS NIH HHS R25 GM062459
6 · The paper itself

Abstract

backgroundMild-hyperthermia therapy (40-45 °C) with high-intensity focused ultrasound (HIFU) is a technique being considered in a number of different treatments such as thermally activated drug delivery, immune-stimulation, and as a chemotherapy adjuvant. Mechanical damage and loss of cell viability associated with HIFU-induced acoustic cavitation may pose a risk during these treatments or may hinder their success. Here we present a method that achieves mild heating and reduces cavitation by using a multi-focused HIFU beam. We quantify cavitation level and temperature rise in multi-focal sonications and compare it to single-focus sonications at the transducer geometric focus.

methodsContinuous wave sonications were performed with the Sonalleve V2 transducer in gel phantoms and pork at 5, 10, 20, 40, 60, 80 acoustic watts for 30 s. Cavitation activity was measured with two ultrasound (US) imaging probes, both by computing the raw channel variance and using passive acoustic mapping (PAM). Temperature rise was measured with MR thermometry at 3 T. Cavitation and heating were compared for single- and multi-focal sonication geometries. Multi-focal sonications used four points equally spaced on a ring of either 4 mm or 8 mm diameter. Single-focus sonications were not steered.

resultsMulti-focal sonication generated distinct foci that were visible in MRI thermal maps in both phantoms and pork, and visible in PAM images in phantoms only. Cavitation activity (measured by channel variance) and mean PAM image value were highly correlated (r > 0.9). In phantoms, cavitation exponentially decreased over the 30-second sonication, consistent with depletion of cavitation nuclei. In pork, sporadic spikes signaling cavitation were observed with single focusing only. In both materials, the widest beam reduced average and peak cavitation level by a factor of two or more at each power tested when compared to a single focus. The widest beam reduced peak temperature by at least 10 °C at powers above 5 W, and created heating that was more spatially diffuse than single focus, resulting in more voxels in the mild heating (3-8 °C) range.

conclusionsMulti-focal HIFU can be used to achieve mild temperature elevation and reduce cavitation activity.

Indexed as

CavitationHigh-intensity focused ultrasound (HIFU)HyperthermiaPassive acoustic mapping

Identifiers

PMID28413682
PMCPMC5390440
OpenAlexW2588499290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.