The tip-apex distance in the X-Bolt dynamic plating system.

M A Fernandez, A Aquilina, J Achten, N Parsons, M L Costa, X L Griffin

Open access · goldAbstract read
In one paragraph

Article in Bone & joint research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

M A FernandezUniversity of Oxford, NDORMS, John Radcliffe Hospital, Oxford OX3 9DU and Specialty Registrar, Trauma and Orthopaedic Surgery, University Hospital Coventry, Clifford Bridge Road, Coventry, CV2 2DX, UK miguel.fernandez@ndorms.ox.ac.uk.
A AquilinaUniversity of Oxford, NDORMS, John Radcliffe Hospital, Oxford OX3 9DU, UK.
J AchtenUniversity of Oxford, NDORMS, John Radcliffe Hospital, Oxford OX3 9DU, UK.
N ParsonsStatistics and Epidemiology Unit, Warwick Medical School, University of Warwick, Gibbet Hill Road, Coventry CV4 7AL, UK.
M L CostaUniversity of Oxford, NDORMS, John Radcliffe Hospital, Oxford OX3 9DU, UK.
X L GriffinUniversity of Oxford, NDORMS, John Radcliffe Hospital, Oxford OX3 9DU, UK.
University of Oxford · GBJohn Radcliffe Hospital · GBUniversity of Warwick · GB

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThe Sliding Hip Screw (SHS) is commonly used to treat trochanteric hip fractures. Fixation failure is a devastating complication requiring complex revision surgery. One mode of fixation failure is lag screw cut-out which is greatest in unstable fracture patterns and when the tip-apex distance of the lag screw is > 25 mm. The X-Bolt Dynamic Hip Plating System (X-Bolt Orthopaedics, Dublin, Ireland) is a new device which aims to reduce this risk of cut-out. However, some surgeons have reported difficulty minimising the tip-apex distance with subsequent concerns that this may lead to an increased risk of cut-out. PATIENTS AND

methodsWe measured the tip-apex distance from the intra-operative radiographs of 93 unstable trochanteric hip fractures enrolled in a randomised controlled trial (Warwick Hip Trauma Evaluation, WHiTE One trial). Participants were treated with either the sliding hip screw or the X-Bolt dynamic hip plating system. We also recorded the incidence of cut-out in both groups, at a median follow-up time of 17 months.

resultsThere was a significantly increased tip-apex distance with the use of the X-Bolt (mean difference 3.7mm (95% confidence interval 1.58 to 5.73); SHS mean 17.1 mm, X-Bolt mean 20.8; p = 0.001. However, this was not associated with an increased incidence of cut-out at a median follow-up time of 17 months, with three cut-outs (6%) in the SHS group and 0 (0%) in the X-Bolt group.

conclusionThe X-Bolt is a safe implant with no increased risk for cut-out. Concerns about minimising the tip-apex distance may be justified but do not appear to be clinically important.

Indexed as

Hip fractureTip-apex distanceX-Bolt