Trial reportThe New England journal of medicine2017
Bioresorbable Scaffolds versus Metallic Stents in Routine PCI.
Trial report in The New England journal of medicine, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT01858077 (Amsterdam Investigator-initiateD Absorb Strategy All-comers Trial), which is not on this map. Cited by 137 papers, 9 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Amsterdam Investigator-initiateD Absorb Strategy All-comers Trial (AIDA Trial): A Clinical Evaluation Comparing the Efficacy and Performance of ABSORB™ Everolimus Eluting Bioresorbable Vascular Scaffold Strategy Versus the XIENCE Family (XIENCE PRIME™ or XIENCE Xpedition™) Everolimus Eluting Coronary Stent Strategy in the Treatment of Coronary Lesions in Consecutive All-comers.
Who cites it
137 citing papers in PubMed, 9 syntheses or guidelines pooled it.
- Preventive percutaneous coronary intervention versus optimal medical therapy for vulnerable plaque: a meta-analysis.BMC cardiovascular disorders · 2025Pooled it
- Comparison of intravascular ultrasound, optical coherence tomography, and conventional angiography-guided percutaneous coronary interventions: A systematic review, network meta-analysis, and meta-regression.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2023Pooled it
- Safety and Efficacy of Bioresorbable Vascular Scaffolds in Coronary Bifurcation Lesions: A Systematic Review and Meta-Analysis.Current cardiology reviews · 2022Pooled it
- Bioresorbable vascular stents and drug-eluting stents in treatment of coronary heart disease: a meta-analysis.Journal of cardiothoracic surgery · 2020Pooled it
- Bioresorbable vascular scaffolds for percutaneous treatment of chronic total coronary occlusions: a meta-analysis.BMC cardiovascular disorders · 2019Pooled it
- Systematic Review and Proportional Meta-Analysis of Endarterectomy and Endovascular Therapy with Routine or Selective Stenting for Common Femoral Artery Atherosclerotic Disease.Journal of interventional cardiology · 2019Pooled it
- Mid-term outcomes of the Absorb BVS versus second-generation DES: A systematic review and meta-analysis.PloS one · 2018Pooled it
- Long-term outcome of bioresorbable vascular scaffolds for the treatment of coronary artery disease: a meta-analysis of RCTs.BMC cardiovascular disorders · 2017Pooled it
- Coronary revascularization in patients with stable coronary disease and diabetes mellitus.Diabetes & vascular disease researchPooled it
- Long-term clinical outcomes of everolimus-eluting bioresorbable scaffolds versus everolimus-eluting stents: final five-year results of the AIDA randomised clinical trial.EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology · 2022Trial
- Five-year angiographic, OCT and clinical outcomes of a randomized comparison of everolimus and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2022Trial
- Three-year clinical outcomes of the absorb bioresorbable vascular scaffold compared to Xience everolimus-eluting stent in routine PCI in patients with diabetes mellitus-AIDA sub-study.Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions · 2021Trial
- Optical coherence tomography tissue coverage and characterization at six months after implantation of bioresorbable scaffolds versus conventional everolimus eluting stents in the ISAR-Absorb MI trial.The international journal of cardiovascular imaging · 2021Trial
- The influence of implantation techniques on lesion oriented-outcomes in Absorb BVS and Xience EES lesions treated in routine clinical practice at complete three year follow-up: AIDA trial QCA substudy.The international journal of cardiovascular imaging · 2020Trial
- Pre-Emptive OCT-Guided Angioplasty of Vulnerable Intermediate Coronary Lesions: Results from the Prematurely Halted PECTUS-Trial.Journal of interventional cardiology · 2020Trial
- The relationship of pre-procedural Dmax based sizing to lesion level outcomes in Absorb BVS and Xience EES treated patients in the AIDA trial.The international journal of cardiovascular imaging · 2019Trial
- Beyond Thirty Days: Risk, Reintervention, and Recovery in Contemporary Cardiovascular Surgery.Journal of cardiovascular development and disease · 2026Article
- Learning from Biodegradable Coronary Stents: Future Directions for TPVR Biodegradable Stents.International journal of molecular sciences · 2026Review
- Sonoenzymatically Triggered Cascading Degradation of Bioresorbable Materials for On-Demand Transient Triboelectric Implants.Advanced materials (Deerfield Beach, Fla.) · 2026Article
- From Caging to Uncaging With Bioadaptors: A Novel Paradigm in Coronary Revascularization.Journal of the American Heart Association · 2026Review
77 more citing papers are in PubMed but not listed here.
Corrections and comments
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
- Commented on by
Authors and funding
17 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundBioresorbable vascular scaffolds were developed to overcome the shortcomings of drug-eluting stents in percutaneous coronary intervention (PCI). We performed an investigator-initiated, randomized trial to compare an everolimus-eluting bioresorbable scaffold with an everolimus-eluting metallic stent in the context of routine clinical practice.
methodsWe randomly assigned 1845 patients undergoing PCI to receive either a bioresorbable vascular scaffold (924 patients) or a metallic stent (921 patients). The primary end point was target-vessel failure (a composite of cardiac death, target-vessel myocardial infarction, or target-vessel revascularization). The data and safety monitoring board recommended early reporting of the study results because of safety concerns. This report provides descriptive information on end-point events.
resultsThe median follow-up was 707 days. Target-vessel failure occurred in 105 patients in the scaffold group and in 94 patients in the stent group (2-year cumulative event rates, 11.7% and 10.7%, respectively; hazard ratio, 1.12; 95% confidence interval [CI], 0.85 to 1.48; P=0.43); event rates were based on Kaplan-Meier estimates in time-to-event analyses. Cardiac death occurred in 18 patients in the scaffold group and in 23 patients in the stent group (2-year cumulative event rates, 2.0% and 2.7%, respectively), target-vessel myocardial infarction occurred in 48 patients in the scaffold group and in 30 patients in the stent group (2-year cumulative event rates, 5.5% and 3.2%), and target-vessel revascularization occurred in 76 patients in the scaffold group and in 65 patients in the stent group (2-year cumulative event rates, 8.7% and 7.5%). Definite or probable device thrombosis occurred in 31 patients in the scaffold group as compared with 8 patients in the stent group (2-year cumulative event rates, 3.5% vs. 0.9%; hazard ratio, 3.87; 95% CI, 1.78 to 8.42; P<0.001).
conclusionsIn this preliminary report of a trial involving patients undergoing PCI, there was no significant difference in the rate of target-vessel failure between the patients who received a bioresorbable scaffold and the patients who received a metallic stent. The bioresorbable scaffold was associated with a higher incidence of device thrombosis than the metallic stent through 2 years of follow-up. (Funded by Abbott Vascular; AIDA ClinicalTrials.gov number, NCT01858077 .).
Indexed as
Identifiers
28402237What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.