Evidence map›Paper›PMID 28398697›Full record

SynthesisThe Cochrane database of systematic reviews2017

Effects of targeting lower versus higher arterial oxygen saturations on death or disability in preterm infants.

Lisa M Askie, Brian A Darlow, Peter G Davis, Neil Finer, Ben Stenson, Maximo Vento, Robin Whyte

Open access · bronzeAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in The Cochrane database of systematic reviews, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 85 papers, 7 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
85citing papers in PubMed, 7 pooled it
22.7field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

85 citing papers in PubMed, 7 syntheses or guidelines pooled it, 206 citations in OpenAlex.

  1. Automated oxygen delivery for preterm infants with respiratory dysfunction.The Cochrane database of systematic reviews · 2023
    Pooled it
  2. Pooled it
  3. Pooled it
  4. Pooled it
  5. Pooled it
  6. Pooled it
  7. Pooled it
  8. Randomised crossover study on pulse oximeter readings from different sensors in very preterm infants.Archives of disease in childhood. Fetal and neonatal edition · 2024
    Trial
  9. Trial
  10. Trial
  11. Review
  12. Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. [Application of intelligent oxygen management system in neonatal intensive care units: a scoping review].Zhongguo dang dai er ke za zhi = Chinese journal of contemporary pediatrics · 2025
    Article
  19. Article
  20. Article

25 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 6 institutions in 5 countries.

Lisa M AskieNHMRC Clinical Trials Centre, University of Sydney, Locked Bag 77, Camperdown, NSW, Australia, 2050.
Brian A DarlowDepartment of Paediatrics, University of Otago, Christchurch, New Zealand.
Peter G DavisThe University of Melbourne, Melbourne, Australia.
Neil FinerDepartment of Pediatrics, University of California San Diego, 200 W Arbor Dr, San Diego, California, USA, 92103-8774.
Ben StensonNeonatal Unit, Simpson Centre for Reproductive Health, Royal Infirmary of Edinburgh, Edinburgh, UK.
Maximo VentoHealth Research Institute La Fe, Division of Neonatology, University & Polytechnic Hospital La Fe, Bulevar Sur s/n, Valencia, Spain, 46026.
Robin WhyteDepartment of Neonatal Pediatrics, Halifax Dalhousie University, IWK Health Centre, 5850/5980 University Avenue, Halifax, NS, Canada, B3K 6R8.
Dalhousie University · CAEdinburgh Royal Infirmary · GBNational Health and Medical Research Council · AURoyal Women's Hospital · AUUniversity of California, San Diego · USUniversity of Otago · NZ

Funding

Prospective Meta-Analysis of Oxygen Saturation Trials in Preterm InfantsR03HD079867 · NICHD · UNIVERSITY OF ALABAMA AT BIRMINGHAM · PI CARLO FONT, WALDEMAR A. · 2014 to 2015
$126k
NICHD NIH HHS R03 HD079867
6 · The paper itself

Abstract

backgroundThe use of supplemental oxygen in the care of extremely preterm infants has been common practice since the 1940s. Despite this, there is little agreement regarding which oxygen saturation (SpO₂) ranges to target to maximise short- or long-term growth and development, while minimising harms. There are two opposing concerns. Lower oxygen levels (targeting SpO₂ at 90% or less) may impair neurodevelopment or result in death. Higher oxygen levels (targeting SpO₂ greater than 90%) may increase severe retinopathy of prematurity or chronic lung disease.The use of pulse oximetry to non-invasively assess neonatal SpO₂ levels has been widespread since the 1990s. Until recently there were no randomised controlled trials (RCTs) that had assessed whether it is better to target higher or lower oxygen saturation levels in extremely preterm infants, from birth or soon thereafter. As a result, there is significant international practice variation and uncertainty remains as to the most appropriate range to target oxygen saturation levels in preterm and low birth weight infants.

objectives1. What are the effects of targeting lower versus higher oxygen saturation ranges on death or major neonatal and infant morbidities, or both, in extremely preterm infants?2. Do these effects differ in different types of infants, including those born at a very early gestational age, or in those who are outborn, without antenatal corticosteroid coverage, of male sex, small for gestational age or of multiple birth, or by mode of delivery? SEARCH

methodsWe used the standard search strategy of Cochrane Neonatal to search the Cochrane Central Register of Controlled Trials (CENTRAL 2016, Issue 4), MEDLINE via PubMed (1966 to 11 April 2016), Embase (1980 to 11 April 2016) and CINAHL (1982 to 11 April 2016). We also searched clinical trials databases, conference proceedings and the reference lists of retrieved articles for randomised controlled trials. SELECTION CRITERIA: Randomised controlled trials that enrolled babies born at less than 28 weeks' gestation, at birth or soon thereafter, and targeted SpO₂ ranges of either 90% or below or above 90% via pulse oximetry, with the intention of maintaining such targets for at least the first two weeks of life. DATA COLLECTION AND ANALYSIS: We used the standard methods of Cochrane Neonatal to extract data from the published reports of the included studies. We sought some additional aggregate data from the original investigators in order to align the definitions of two key outcomes. We conducted the meta-analyses with Review Manager 5 software, using the Mantel-Haenszel method for estimates of typical risk ratio (RR) and risk difference (RD) and a fixed-effect model. We assessed the included studies using the Cochrane 'Risk of bias' and GRADE criteria in order to establish the quality of the evidence. We investigated heterogeneity of effects via pre-specified subgroup and sensitivity analyses. MAIN

resultsFive trials, which together enrolled 4965 infants, were eligible for inclusion. The investigators of these five trials had prospectively planned to combine their data as part of the NeOProM (Neonatal Oxygen Prospective Meta-analysis) Collaboration. We graded the quality of evidence as high for the key outcomes of death, major disability, the composite of death or major disability, and necrotising enterocolitis; and as moderate for blindness and retinopathy of prematurity requiring treatment.When an aligned definition of major disability was used, there was no significant difference in the composite primary outcome of death or major disability in extremely preterm infants when targeting a lower (SpO₂ 85% to 89%) versus a higher (SpO₂ 91% to 95%) oxygen saturation range (typical RR 1.04, 95% confidence interval (CI) 0.98 to 1.10; typical RD 0.02, 95% CI -0.01 to 0.05; 5 trials, 4754 infants) (high-quality evidence). Compared with a higher target range, a lower target range significantly increased the incidence of death at 18 to 24 months corrected age (typical RR 1.16, 95% CI 1.03 to 1.31; typical RD 0.03, 95% CI 0.01 to 0.05; 5 trials, 4873 infants) (high-quality evidence) and necrotising enterocolitis (typical RR 1.24, 95% 1.05 to 1.47; typical RD 0.02, 95% CI 0.01 to 0.04; 5 trials, 4929 infants; I² = 0%) (high-quality evidence). Targeting the lower range significantly decreased the incidence of retinopathy of prematurity requiring treatment (typical RR 0.72, 95% CI 0.61 to 0.85; typical RD -0.04, 95% CI -0.06 to -0.02; 5 trials, 4089 infants; I² = 69%) (moderate-quality evidence). There were no significant differences between the two treatment groups for major disability including blindness, severe hearing loss, cerebral palsy, or other important neonatal morbidities.A subgroup analysis of major outcomes by type of oximeter calibration software (original versus revised) found a significant difference in the treatment effect between the two software types for death (interaction P = 0.03), with a significantly larger treatment effect seen for those infants using the revised algorithm (typical RR 1.38, 95% CI 1.13 to 1.68; typical RD 0.06, 95% CI 0.01 to 0.10; 3 trials, 1716 infants). There were no other important differences in treatment effect shown by the subgroup analyses using the currently available data. AUTHORS'

conclusionsIn extremely preterm infants, targeting lower (85% to 89%) SpO₂ compared to higher (91% to 95%) SpO₂ had no significant effect on the composite outcome of death or major disability or on major disability alone, including blindness, but increased the average risk of mortality by 28 per 1000 infants treated. The trade-offs between the benefits and harms of the different oxygen saturation target ranges may need to be assessed within local settings (e.g. alarm limit settings, staffing, baseline outcome risks) when deciding on oxygen saturation targeting policies.

Indexed as

Infant, Extremely PrematureInfant MortalityAge FactorsArteriesBlindnessCerebral PalsyEnterocolitis, NecrotizingHumansIncidenceInfantInfant, NewbornOximetryOxygenPublication BiasRandomized Controlled Trials as TopicRetinopathy of PrematurityOxygen

Identifiers

PMID28398697
PMCPMC6478245
OpenAlexW1544295278

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.