ArticleIEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation2016

Catadioptric Stereo Tracking for Three Dimensional Shape Measurement of MRI Guided Catheters.

Russell C Jackson, Taoming Liu, M Cenk Çavuşoğlu

Abstract read
In one paragraph

Article in IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Free-Space Dynamic Modeling of an MRI-Actuated Robotic Catheter.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2025
    Article
  3. Analysis of Dynamic Response of an MRI-Guided Magnetically-Actuated Steerable Catheter System.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2018
    Article
  4. State Estimation for MRI-Actuated Catheters via Catadioptric Stereo Camera.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2018
    Article
  5. Iterative Jacobian-Based Inverse Kinematics and Open-Loop Control of an MRI-Guided Magnetically Actuated Steerable Catheter System.IEEE/ASME transactions on mechatronics : a joint publication of the IEEE Industrial Electronics Society and the ASME Dynamic Systems and Control Division · 2017
    Article
  6. Experimental Validation of the Pseudo-Rigid-Body Model of the MRI-Actuated Catheter.IEEE International Conference on Robotics and Automation : ICRA : [proceedings]. IEEE International Conference on Robotics and Automation
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Russell C JacksonDepartment of Electrical Engineering and Computer Science (EECS) at Case Western Reserve University in Cleveland, OH, USA.
Taoming LiuDepartment of Electrical Engineering and Computer Science (EECS) at Case Western Reserve University in Cleveland, OH, USA.
M Cenk ÇavuşoğluDepartment of Electrical Engineering and Computer Science (EECS) at Case Western Reserve University in Cleveland, OH, USA.

Funding

NRI: Small: Magnetic Resonance Imaging Guided Co-Robotic Active Catheter SystemR01EB018108 · NIBIB · CASE WESTERN RESERVE UNIVERSITY · PI CAVUSOGLU, M. CENK · 2013 to 2016
$1.3M
NIBIB NIH HHS R01 EB018108
6 · The paper itself

Abstract

The recent introduction of Magnetic Resonance Imaging (MRI)-actuated steerable catheters lays the ground work for increasing the efficacy of cardiac catheter procedures. The MRI, while capable of imaging the catheter for tracking and control, does not fulfill all of the needs required to identify and develop a complete catheter model. Specifially, the frequency response of the catheter must be identified to ensure stable control of the catheter system. This requires a higher frequency imaging than the MRI can achieve. This work uses a catadioptric stereo camera system consisting of a mirror and a single camera in order to track a MRI actuated catheter inside a MRI machine. The catadioptric system works in parallel to the MRI and is capable of recording the catheter at 60 fps for post processing. The accuracy of the catadioptric system is verified in imaging conditions that would be found inside the MRI. The stereo camera is then used to track a catheter as it is actuated inside the MRI.

Identifiers

PMID28392968
PMCPMC5382962

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390