Evidence map›Paper›PMID 28392492›Full record

ReviewNeuroImage2018

Pulse sequences and parallel imaging for high spatiotemporal resolution MRI at ultra-high field.

Benedikt A Poser, Kawin Setsompop

Abstract readReview
In one paragraph

Review in NeuroImage, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Micron-resolution Imaging of Cortical Bone under 14 T Ultrahigh Magnetic Field.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  6. Review
  7. The photobiology of the human circadian clock.Proceedings of the National Academy of Sciences of the United States of America · 2022
    Article
  8. Article
  9. Review
  10. Article
  11. Linking cortical circuit models to human cognition with laminar fMRI.Neuroscience and biobehavioral reviews · 2021
    Review
  12. Challenges and opportunities of mesoscopic brain mapping with fMRI.Current opinion in behavioral sciences · 2021
    Article
  13. Article
  14. Review
  15. Review
  16. Article
  17. Review
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Benedikt A PoserDepartment of Cognitive Neuroscience, Faculty of Psychology and Neuroscience, Maastricht University, Maastricht, Netherlands. Electronic address: benedikt.poser@maastrichtuniversity.nl.
Kawin SetsompopDepartment of Radiology, Harvard Medical School, Boston, MA, USA; Athinoula A. Martinos Center for Biomedical Imaging, Massachusetts General Hospital, Charlestown, MA, USA.

Funding

Project 4P41EB015896 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI ROSEN, BRUCE R · 2012 to 2018
$9.8M
fMRI Technologies for Imaging at the Limit of Biological Spatiotemporal Resolution: Administrative SupplementR01EB019437 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI POLIMENI, JONATHAN RIZZO, SETSOMPOP, KAWIN · 2015 to 2024
$5.5M
Foundations of MRI Corticography for mesoscale organization and neuronal circuitryR01MH111444 · NIMH · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN · 2016 to 2020
$5.1M
Rapid MRI acquisition for pediatric low-grade gliomasR01EB020613 · NIBIB · STANFORD UNIVERSITY · PI SETSOMPOP, KAWIN · 2016 to 2019
$2.5M
MRI Corticography (MRCoG): Micro-scale Human Cortical ImagingR24MH106096 · NIMH · UNIVERSITY OF CALIFORNIA BERKELEY · PI FEINBERG, DAVID ALAN, LIU, CHUNLEI · 2014 to 2016
$1.4M
NIBIB NIH HHS P41 EB015896NIBIB NIH HHS R01 EB019437NIBIB NIH HHS R01 EB020613NIMH NIH HHS R01 MH111444NIMH NIH HHS R24 MH106096
6 · The paper itself

Abstract

The SNR and CNR benefits of ultra-high field (UHF) have helped push the envelope of achievable spatial resolution in MRI. For applications based on susceptibility contrast where there is a large CNR gain, high quality sub-millimeter resolution imaging is now being routinely performed, particularly in fMRI and phase imaging/QSM. This has enabled the study of structure and function of very fine-scale structures in the brain. UHF has also helped push the spatial resolution of many other MRI applications as will be outlined in this review. However, this push in resolution comes at a cost of a large encoding burden leading to very lengthy scans. Developments in parallel imaging with controlled aliasing and the move away from 2D slice-by-slice imaging to much more SNR-efficient simultaneous multi-slice (SMS) and 3D acquisitions have helped address this issue. In particular, these developments have revolutionized the efficiency of UHF MRI to enable high spatiotemporal resolution imaging at an order of magnitude faster acquisition. In addition to describing the main approaches to these techniques, this review will also outline important key practical considerations in using these methods in practice. Furthermore, new RF pulse design to tackle the B

Indexed as

BrainFunctional NeuroimagingHemodynamicsHumansMagnetic Resonance ImagingBOLD fMRICAIPIRINHAdw-EPIParallel imagingQSMSimultaneous multi-sliceStructural MRIUltra-high fieldWave-CAIPI

Identifiers

PMID28392492
PMCPMC5630499

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.