ArticleIEEE transactions on medical imaging2017
4-D Reconstruction With Respiratory Correction for Gated Myocardial Perfusion SPECT.
Article in IEEE transactions on medical imaging, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
8 citing papers in PubMed.
- Investigation of Attenuation Correction Methods for Dual-Gated Single Photon Emission Computed Tomography (DG-SPECT).Bioengineering (Basel, Switzerland) · 2025Article
- A review of state-of-the-art resolution improvement techniques in SPECT imaging.EJNMMI physics · 2025Review
- Current Research Status of Respiratory Motion for Thorax and Abdominal Treatment: A Systematic Review.Biomimetics (Basel, Switzerland) · 2024Review
- Deep learning with noise-to-noise training for denoising in SPECT myocardial perfusion imaging.Medical physics · 2021Article
- Improving perfusion defect detection with respiratory motion correction in cardiac SPECT at standard and reduced doses.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- Personalized Models for Injected Activity Levels in SPECT Myocardial Perfusion Imaging.IEEE transactions on medical imaging · 2019Article
- Effect of respiratory motion on cardiac defect contrast in myocardial perfusion SPECT: a physical phantom study.Annals of nuclear medicine · 2019Article
- Cardiac motion correction for improving perfusion defect detection in cardiac SPECT at standard and reduced doses of activity.Physics in medicine and biology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
Abstract
Cardiac single photon emission computed tomography (SPECT) images are known to suffer from both cardiac and respiratory motion blur. In this paper, we investigate a 4-D reconstruction approach to suppress the effect of respiratory motion in gated cardiac SPECT imaging. In this approach, the sequence of cardiac gated images is reconstructed with respect to a reference respiratory amplitude bin in the respiratory cycle. To combat the challenge of inherent high-imaging noise, we utilize the data counts acquired during the entire respiratory cycle by making use of a motion-compensated scheme, in which both cardiac motion and respiratory motion are taken into account. In the experiments, we first use Monte Carlo simulated imaging data, wherein the ground truth is known for quantitative comparison. We then demonstrate the proposed approach on eight sets of clinical acquisitions, in which the subjects exhibit different degrees of respiratory motion blur. The quantitative evaluation results show that the 4-D reconstruction with respiratory correction could effectively reduce the effect of motion blur and lead to a more accurate reconstruction of the myocardium. The mean-squared error of the myocardium is reduced by 22%, and the left ventricle (LV) resolution is improved by 21%. Such improvement is also demonstrated with the clinical acquisitions, where the motion blur is markedly improved in the reconstructed LV wall and blood pool. The proposed approach is also noted to be effective on correcting the spill-over effect in the myocardium from nearby bowel or liver activities.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.