Evidence map›Paper›PMID 28384558›Full record

ArticleInternational journal of surgery case reports2017

Temporary total hip arthroplasty-like spacer for treating an infected periprosthetic femoral fracture using a long stem: A case report.

Youngwoo Kim, Yoshiaki Katsura, Nina Kasahara, Takashi Kasahara, Masashi Kanamura, Keiichi Kawanabe

Open access · goldAbstract read
In one paragraph

Article in International journal of surgery case reports, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.2field-weighted citation impact, top 42% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Youngwoo KimDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: woochan76@hotmail.co.jp.
Yoshiaki KatsuraDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: QYF07360@nifty.com.
Nina KasaharaDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: 27@mail.goo.ne.jp.
Takashi KasaharaDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: kasahara520325@gmail.com.
Masashi KanamuraDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: nra09812@nifty.com.
Keiichi KawanabeDepartment of Orthopaedics, Shiga Medical Center for Adults, 5-4-30 Moriyama, Moriyama, Shiga, Japan. Electronic address: kawanabe@mdc.med.shiga-pref.jp.
Shiga Medical Center · JPShiga Medical Center for Adults · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionInfected periprosthetic femoral fractures are among the most complex and significant complications of total hip arthroplasty (THA). We report the novel use of a temporary THA-like spacer for treating an infected periprosthetic femoral fracture after revision surgery using a long stem. CASE PRESENTATION: We present a 72-year-old woman sustained a left infected periprosthetic femoral fracture after revi - streptococci in the culture sample. On suspicion of a periprosthetic joint infection, we planned a two-stage procedure. We used a temporary THA-like spacer comprising the removed femoral long stem, which was autoclaved and then reimplanted, and applied a new polyethylene acetabular liner. Both components were cemented in place with antibioticloaded bone cement, without applying strong pressure. Pain control waseasily achieved postoperatively because the fracture had been stabilized early. The THA-like spacer was stable, and allowed a good range of motion without pain. She was allowed to move with a wheelchair and was walk with partial weight bearing without pain. Seven week after the initial THAlike spacer placement, we performed a revision THA after successful control of infection. At the 1-year follow-up, the patient remained free of infection.

conclusionsTemporary antibiotic-loaded cement-coated THA-like spacer using a long stem facilitated the eradication of infection, fracture stabilization, and enables partial weight bearing without pain.

Indexed as

Infected periprosthetic femoral fractureLong stemTHA-like spacerTotal hip arthroplasty

Identifiers

PMID28384558
PMCPMC5382027
OpenAlexW2599930343

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.