Geometric calibration and correction for a lens-coupled detector in x-ray phase-contrast imaging.

Alex George, Peter Y Chen, Alejandro Morales-Martinez, Alireza Panna, Andrew A Gomella, Eric E Bennett, Han Wen

Open access · bronzeAbstract read
In one paragraph

Article in Journal of medical imaging (Bellingham, Wash.), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.3field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Alex GeorgeNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Peter Y ChenNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Alejandro Morales-MartinezNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Alireza PannaNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Andrew A GomellaNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Eric E BennettNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
Han WenNational Institutes of Health , National Heart, Lung and Blood Institute, Biochemistry and Biophysics Center, Imaging Physics Laboratory, Bethesda, Maryland, United States.
National Institutes of Health · USNational Heart Lung and Blood Institute · US

Funding

X-Ray Phase Contrast Imaging Concepts and SystemsZIAHL004606 · NHLBI · NATIONAL HEART, LUNG, AND BLOOD INSTITUTE · PI WEN, HAN · 2009 to 2022
$10.1M
6 · The paper itself

Abstract

A lens-coupled x-ray camera with a tilted phosphor collects light emission from the x-ray illuminated (front) side of phosphor. Experimentally, it has been shown to double x-ray photon capture efficiency and triple the spatial resolution along the phosphor tilt direction relative to the same detector at normal phosphor incidence. These characteristics benefit grating-based phase-contrast methods, where linear interference fringes need to be clearly resolved. However, both the shallow incident angle on the phosphor and lens aberrations of the camera cause geometric distortions. When tiling multiple images of limited vertical view into a full-field image, geometric distortion causes blurring due to image misregistration. Here, we report a procedure of geometric correction based on global polynomial transformation of image coordinates. The corrected image is equivalent to one obtained with a single full-field flat panel detector placed at the sample plane. In a separate evaluation scan, the position deviations in the horizontal and vertical directions were reduced from 0.76 and 0.028 mm, respectively, to 0.006 and 0.009 mm, respectively, by the correction procedure, which were below the 0.028-mm pixel size of the imaging system. In a demonstration of a phase-contrast imaging experiment, the correction reduced blurring of small structures.

Indexed as

geometric correctionimage distortionphase contrasttilted phosphorx-ray

Identifiers

PMID28382313
PMCPMC5364952
OpenAlexW2599982562

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.