The effects of iterative reconstruction and kernel selection on quantitative computed tomography measures of lung density.
Article in Medical physics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 22 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
22 citing papers in PubMed, 30 citations in OpenAlex.
- Characterizing heterogeneity and subphenotyping acute respiratory distress syndrome with computed tomography.Intensive care medicine experimental · 2026Review
- Prevalence and regional distribution of osteoporosis in adults aged 75 years and older: a quantitative computed tomography-based retrospective cross-sectional study.BMC geriatrics · 2026Article
- Application of deep learning reconstruction at prone position chest scanning of early interstitial lung disease.BMC medical imaging · 2025Article
- Effect of slice thickness on quantitative analysis of interstitial lung disease: a retrospective volumetric chest CT study.La Radiologia medica · 2025Article
- Identification of the optimal threshold for predicting the infiltration degree of T1-stage lung adenocarcinoma using solid component volume and three-dimensional consolidation-to-tumor ratio in threshold segmentation.Quantitative imaging in medicine and surgery · 2025Article
- Lung densitometry in postmortem computed tomography - comparison across different fatal asphyxia groups.Forensic science, medicine, and pathology · 2025Article
- Investigating the impact of kernel harmonization and deformable registration on inspiratory and expiratory chest CT images for people with COPD.Proceedings of SPIE--the International Society for Optical Engineering · 2025Article
- Pulmonary emphysema: the assessment of lung perfusion with Dual-Energy CT and pulmonary scintigraphy.La Radiologia medica · 2024Article
- Article
- Can deep learning improve image quality of low-dose CT: a prospective study in interstitial lung disease.European radiology · 2022Article
- Harmonization of in-plane resolution in CT using multiple reconstructions from single acquisitions.Medical physics · 2021Article
- QIBA guidance: Computed tomography imaging for COVID-19 quantitative imaging applications.Clinical imaging · 2021Article
- A calibration CT mini-lung-phantom created by 3-D printing and subtractive manufacturing.Journal of applied clinical medical physics · 2021Article
- Optimization of HU threshold for coronary artery calcium scans reconstructed at 0.5-mm slice thickness using iterative reconstruction.Journal of applied clinical medical physics · 2020Article
- Potential for dose reduction in CT emphysema densitometry with post-scan noise reduction: a phantom study.The British journal of radiology · 2020Article
- Influence of acquisition settings and radiation exposure on CT lung densitometry-An anthropomorphic ex vivo phantom study.PloS one · 2020Article
- Validated imaging biomarkers as decision-making tools in clinical trials and routine practice: current status and recommendations from the EIBALL* subcommittee of the European Society of Radiology (ESR).Insights into imaging · 2019Article
- Harmonization of chest CT scans for different doses and reconstruction methods.Medical physics · 2019Article
- Lumen area change (Delta Lumen) between inspiratory and expiratory multidetector computed tomography as a measure of severe outcomes in asthmatic patients.The Journal of allergy and clinical immunology · 2018Article
- Pulmonary quantitative CT imaging in focal and diffuse disease: current research and clinical applications.The British journal of radiology · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 1 country.
Funding
Abstract
purposeTo determine the effects of iterative reconstruction (IR) and high-frequency kernels on quantitative computed tomography (qCT) density measures at reduced X-ray dose. MATERIALS AND
methodsThe COPDGene 2 Phantom (CTP 698, The Phantom Laboratory, Salem, NY) with four embedded lung mimicking foam densities (12lb, 20lb, and 4lb), as well as water, air, and acrylic reference inserts, was imaged using a GE 64 slice CT750 HD scanner in helical mode with four current-time products ranging from 12 to 100 mAs. The raw acquired data were reconstructed using standard (STD - low frequency) and Bone (high frequency) kernels with filtered back projection (FBP), 100% ASiR, and Veo reconstruction algorithms. The reference density inserts were manually segmented using Slicer3D (www.slicer.org), and the mean, standard deviation, and histograms of the segmented regions were generated using Fiji (http://fiji.sc/Fiji) for each reconstruction. Measurements of threshold values placed on the cumulative frequency distribution of voxels determined by these measured histograms at 5%, PD5
resultsThe use of high-resolution kernels in conjunction with ASiR and Veo did not significantly affect the mean Hounsfield units (HU) of each of the density standards (< 4 HU deviation) and current-time products within the phantom when compared with the STD+FBP reconstruction conventionally used in clinical applications. A truncation of the scanner reported HU values at -1024 that shifts the mean toward more positive values was found to cause a systematic error in lower attenuating regions. Use of IR drove convergence toward the mean of measured histograms (~100-137% increase in the number measured voxels at the mean of the histogram), while the combination of Bone+ASiR preserved the standard deviation of HU values about the mean compared to STD+FBP, with the added effect of improved spatial resolution and accuracy in airway measures. PD5
conclusionsExtension of the scanner reportable HU values below the present limit of -1024 will mitigate discrepancies found in qCT lung densitometry in low-density regions. The density histogram became more sharply peaked, and standard deviation was reduced for IR, directly effecting density thresholds, PD5