Evidence map›Paper›PMID 28375165›Full record

ArticleSensors (Basel, Switzerland)2017

Power MOSFET Linearizer of a High-Voltage Power Amplifier for High-Frequency Pulse-Echo Instrumentation.

Hojong Choi, Park Chul Woo, Jung-Yeol Yeom, Changhan Yoon

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.

0numbers the graph read from it
0cells of the map it votes in
21citing papers in PubMed
4.1field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

21 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.Technology and health care : official journal of the European Society for Engineering and Medicine · 2022
    Article
  5. Article
  6. Article
  7. Article
  8. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes.Technology and health care : official journal of the European Society for Engineering and Medicine · 2021
    Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Applied current thermoacoustic imaging for biological tissues.Technology and health care : official journal of the European Society for Engineering and Medicine · 2020
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Hojong ChoiDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea. hojongch@kumoh.ac.kr.
Park Chul WooDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea. pcw3108@kumoh.ac.kr.
Jung-Yeol YeomSchool of Biomedical Engineering, Korea University, Seoul 02841, Korea. jungyeol@korea.ac.kr.
Changhan YoonDepartment of Biomedical Engineering, Inje University, Gimhae 50834, Korea. cyoon@inje.ac.kr.
Kumoh National Institute of Technology · KRInje University · KRKorea University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A power MOSFET linearizer is proposed for a high-voltage power amplifier (HVPA) used in high-frequency pulse-echo instrumentation. The power MOSFET linearizer is composed of a DC bias-controlled series power MOSFET shunt with parallel inductors and capacitors. The proposed scheme is designed to improve the gain deviation characteristics of the HVPA at higher input powers. By controlling the MOSFET bias voltage in the linearizer, the gain reduction into the HVPA was compensated, thereby reducing the echo harmonic distortion components generated by the ultrasonic transducers. In order to verify the performance improvement of the HVPA implementing the power MOSFET linearizer, we measured and found that the gain deviation of the power MOSFET linearizer integrated with HVPA under 10 V DC bias voltage was reduced (-1.8 and -0.96 dB, respectively) compared to that of the HVPA without the power MOSFET linearizer (-2.95 and -3.0 dB, respectively) when 70 and 80 MHz, three-cycle, and 26 dB

Indexed as

high-voltage power amplifierpower MOSFET linearizerultrasonic transducer

Identifiers

PMID28375165
PMCPMC5421724
OpenAlexW2604159566

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.