Evidence map›Paper›PMID 28374350›Full record

Observational studyClinical orthopaedics and related research2017

Teaching the Basics: Development and Validation of a Distal Radius Reduction and Casting Model.

Mark A Seeley, Peter D Fabricant, J Todd R Lawrence

Open access · bronzeAbstract readObservational StudyValidation Study
In one paragraph

Observational study in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
1.7field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 29 citations in OpenAlex.

  1. Article
  2. Review
  3. Orthopaedics and Biomedical Engineering Design: An Innovative Duet toward a Better Tomorrow.Journal of the Pediatric Orthopaedic Society of North America · 2023
    Review
  4. Article
  5. Simulation training to retool practicing orthopedic surgeons is rare.Global surgical education : journal of the Association for Surgical Education · 2023
    Review
  6. Article
  7. Ponseti Clubfoot Casting: Factors That Affect Trainee Competency (Retrospective Observational Study).Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2022
    Observational
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

Mark A SeeleyGeisinger Medical Center, 100 N Academy Avenue, Danville, PA, 17821, USA. mseeley1@geisinger.edu.
Peter D FabricantHospital for Special Surgery, New York, NY, USA.
J Todd R LawrenceChildren's Hospital of Philadelphia, Philadelphia, PA, USA.
Children's Hospital of Philadelphia · USGeisinger Medical Center · USHospital for Special Surgery · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundApproximately one-third of reduced pediatric distal radius fractures redisplace, resulting in further treatment. Two major modifiable risk factors for loss of reduction are reduction adequacy and cast quality. Closed reduction and immobilization of distal radius fractures is an Accreditation Council for Graduate Medical Education residency milestone. Teaching and assessing competency could be improved with a life-like simulation training tool. QUESTIONS/PURPOSES: Our goal was to develop and validate a realistic distal radius fracture reduction and casting simulator as determined by (1) a questionnaire regarding the "realism" of the model and (2) the quantitative assessments of reduction time, residual angulation, and displacement.

methodsA distal radius fracture model was created with radiopaque bony segments and articulating elbows and shoulders. Simulated periosteum and internal deforming forces required proper reduction and casting techniques to achieve and maintain reduction. The forces required were estimated through an iterative process through feedback from experienced clinicians. Embedded monofilaments allowed for quantitative assessment of residual displacement and angulation through the use of fluoroscopy. Subjects were asked to perform closed reduction and apply a long arm fiberglass cast. Primary performance variables assessed included reduction time, residual angulation, and displacement. Secondary performance variables consisted of number of fluoroscopic images, casting time, and cast index (defined as the ratio of the internal width of the forearm cast in the sagittal plane to the internal width in the coronal plane at the fracture site). Subject grading was performed by two blinded reviewers. Interrater reliability was nearly perfect across all measurements (intraclass correlation coefficient range, 0.94-0.99), thus disagreements in measurements were handled by averaging the assessed values. After completion the participants answered a Likert-based questionnaire regarding the realism of simulation. Eighteen participants consented to participate in the study (eight attending pediatric orthopaedic surgeons, six junior residents, four senior residents). The performances of junior residents (Postgraduate Year [PGY] 1-2), senior residents (PGY 3-5), and attending surgeons were compared using one-way ANOVA with Tukey's-adjusted pairwise comparisons.

resultsThe majority of participants (15 of 18) felt that the model looked, felt, and moved like a human forearm. All participants strongly agreed that the model taught the basic steps of fracture reduction and should be implemented in orthopaedic training. Attending surgeons reduced fractures in less time than junior residents (60 ± 27 seconds versus 460 ± 62 seconds; mean difference, 400 seconds; 95% CI, 335-465 seconds; p < 0.001). Residual angulation was greater for junior residents when compared with attending surgeons on AP (7° ± 5° versus 0.7° ± 0.9°; mean difference, 6.3°; 95% CI, 3°-11°; p = 0.003) and lateral (27° ± 7° versus 7° ± 5°; mean difference, 20°; 95% CI, 13°-27°; p = 0.001) radiographs. Similarly, residual displacement was greater for junior residents than either senior residents (mean difference, 16 mm; 95% CI, 2-34 mm; p = 0.05) or attending surgeons (mean difference, 15 mm; 95% CI, 3-27 mm; p = 0.02) on lateral images. There were no differences identified in secondary performance variables (number of fluoroscopic images, casting time, and cast index) between groups.

conclusionsThis is the first distal radius fracture reduction model to incorporate an elbow and shoulder and allow quantitative assessment of the fracture reduction. This simulator may be useful in an orthopaedic resident training program to help them reach a defined minimum level of competency. This simulator also could easily be integrated in other accreditation and training programs, including emergency medicine. LEVEL OF EVIDENCE: Level II, therapeutic study.

Indexed as

Casts, SurgicalClinical CompetenceEducation, Medical, GraduateFracture FixationHumansInternship and ResidencyMedical Staff, HospitalModels, AnatomicObserver VariationOperative TimeOrthopedicsOrthopedic SurgeonsProspective StudiesRadius FracturesReproducibility of ResultsSimulation Training

Identifiers

PMID28374350
PMCPMC5539021
OpenAlexW2605294287

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.