ArticlePhysics in medicine and biology2017
Task-driven optimization of CT tube current modulation and regularization in model-based iterative reconstruction.
Article in Physics in medicine and biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Discrimination tasks in simulated low-dose CT noise.Medical physics · 2023Article
- A scanner-specific framework for simulating CT images with tube current modulation.Physics in medicine and biology · 2021Article
- Dual source hybrid spectral micro-CT using an energy-integrating and a photon-counting detector.Physics in medicine and biology · 2020Article
- Task-driven source-detector trajectories in cone-beam computed tomography: I. Theory and methods.Journal of medical imaging (Bellingham, Wash.) · 2019Article
- Task-driven source-detector trajectories in cone-beam computed tomography: II. Application to neuroradiology.Journal of medical imaging (Bellingham, Wash.) · 2019Article
- Predicting image properties in penalized-likelihood reconstructions of flat-panel CBCT.Medical physics · 2019Article
- Statistical weights for model-based reconstruction in cone-beam CT with electronic noise and dual-gain detector readout.Physics in medicine and biology · 2018Article
- Image quality and dose characteristics for an O-arm intraoperative imaging system with model-based image reconstruction.Medical physics · 2018Article
- Dynamic fluence field modulation for miscentered patients in computed tomography.Journal of medical imaging (Bellingham, Wash.) · 2018Article
- Low-dose cone-beam CT via raw counts domain low-signal correction schemes: Performance assessment and task-based parameter optimization (Part II. Task-based parameter optimization).Medical physics · 2018Article
- Task-Driven Optimization of Fluence Field and Regularization for Model-Based Iterative Reconstruction in Computed Tomography.IEEE transactions on medical imaging · 2017Article
- Effects of Image Quality on the Fundamental Limits of Image Registration Accuracy.IEEE transactions on medical imaging · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Tube current modulation (TCM) is routinely adopted on diagnostic CT scanners for dose reduction. Conventional TCM strategies are generally designed for filtered-backprojection (FBP) reconstruction to satisfy simple image quality requirements based on noise. This work investigates TCM designs for model-based iterative reconstruction (MBIR) to achieve optimal imaging performance as determined by a task-based image quality metric. Additionally, regularization is an important aspect of MBIR that is jointly optimized with TCM, and includes both the regularization strength that controls overall smoothness as well as directional weights that permits control of the isotropy/anisotropy of the local noise and resolution properties. Initial investigations focus on a known imaging task at a single location in the image volume. The framework adopts Fourier and analytical approximations for fast estimation of the local noise power spectrum (NPS) and modulation transfer function (MTF)-each carrying dependencies on TCM and regularization. For the single location optimization, the local detectability index (d') of the specific task was directly adopted as the objective function. A covariance matrix adaptation evolution strategy (CMA-ES) algorithm was employed to identify the optimal combination of imaging parameters. Evaluations of both conventional and task-driven approaches were performed in an abdomen phantom for a mid-frequency discrimination task in the kidney. Among the conventional strategies, the TCM pattern optimal for FBP using a minimum variance criterion yielded a worse task-based performance compared to an unmodulated strategy when applied to MBIR. Moreover, task-driven TCM designs for MBIR were found to have the opposite behavior from conventional designs for FBP, with greater fluence assigned to the less attenuating views of the abdomen and less fluence to the more attenuating lateral views. Such TCM patterns exaggerate the intrinsic anisotropy of the MTF and NPS as a result of the data weighting in MBIR. Directional penalty design was found to reinforce the same trend. The task-driven approaches outperform conventional approaches, with the maximum improvement in d' of 13% given by the joint optimization of TCM and regularization. This work demonstrates that the TCM optimal for MBIR is distinct from conventional strategies proposed for FBP reconstruction and strategies optimal for FBP are suboptimal and may even reduce performance when applied to MBIR. The task-driven imaging framework offers a promising approach for optimizing acquisition and reconstruction for MBIR that can improve imaging performance and/or dose utilization beyond conventional imaging strategies.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.