Evidence map›Paper›PMID 28355300›Full record

ArticlePloS one2017

Evaluation of synthetic vascular grafts in a mouse carotid grafting model.

Alex H P Chan, Richard P Tan, Praveesuda L Michael, Bob S L Lee, Laura Z Vanags, Martin K C Ng, Christina A Bursill, Steven G Wise

Abstract readEvaluation Study
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alex H P ChanThe Heart Research Institute, Sydney, New South Wales, Australia.ORCID http://orcid.org/0000-0002-1244-7673
Richard P TanThe Heart Research Institute, Sydney, New South Wales, Australia.
Praveesuda L MichaelThe Heart Research Institute, Sydney, New South Wales, Australia.
Bob S L LeeThe Heart Research Institute, Sydney, New South Wales, Australia.
Laura Z VanagsThe Heart Research Institute, Sydney, New South Wales, Australia.
Martin K C NgThe Heart Research Institute, Sydney, New South Wales, Australia.
Christina A BursillThe Heart Research Institute, Sydney, New South Wales, Australia.
Steven G WiseThe Heart Research Institute, Sydney, New South Wales, Australia.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Current animal models for the evaluation of synthetic grafts are lacking many of the molecular tools and transgenic studies available to other branches of biology. A mouse model of vascular grafting would allow for the study of molecular mechanisms of graft failure, including in the context of clinically relevant disease states. In this study, we comprehensively characterise a sutureless grafting model which facilitates the evaluation of synthetic grafts in the mouse carotid artery. Using conduits electrospun from polycaprolactone (PCL) we show the gradual development of a significant neointima within 28 days, found to be greatest at the anastomoses. Histological analysis showed temporal increases in smooth muscle cell and collagen content within the neointima, demonstrating its maturation. Endothelialisation of the PCL grafts, assessed by scanning electron microscopy (SEM) analysis and CD31 staining, was near complete within 28 days, together replicating two critical aspects of graft performance. To further demonstrate the potential of this mouse model, we used longitudinal non-invasive tracking of bone-marrow mononuclear cells from a transgenic mouse strain with a dual reporter construct encoding both luciferase and green fluorescent protein (GFP). This enabled characterisation of mononuclear cell homing and engraftment to PCL using bioluminescence imaging and histological staining over time (7, 14 and 28 days). We observed peak luminescence at 7 days post-graft implantation that persisted until sacrifice at 28 days. Collectively, we have established and characterised a high-throughput model of grafting that allows for the evaluation of key clinical drivers of graft performance.

Indexed as

Blood Vessel ProsthesisDisease Models, AnimalActinsAnimalsCarotid ArteriesCell TrackingCollagenFemaleGreen Fluorescent ProteinsHyperplasiaLuminescent MeasurementsMice, Inbred C57BLMice, TransgenicMicroscopy, Electron, ScanningMyocytes, Smooth MuscleNeointimaActinsCollagenGreen Fluorescent ProteinspolycaprolactonePolyesters

Identifiers

PMID28355300
PMCPMC5371373

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.