ArticleJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2018
Development and validation of an automatic method to detect the latest contracting viable left ventricular segments to assist guide CRT therapy from gated SPECT myocardial perfusion imaging.
Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 22 citations in OpenAlex.
- Value of intraventricular dyssynchrony assessment by gated-SPECT myocardial perfusion imaging in the management of heart failure patients undergoing cardiac resynchronization therapy (VISION-CRT).Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Trial
- Mechanical dyssynchrony and diastolic dysfunction are common in LVH: a pilot correlation study using Doppler echocardiography and CZT gated-SPECT MPI.Scientific reports · 2018Trial
- A New Method of Modeling the Multi-stage Decision-Making Process of CRT Using Machine Learning with Uncertainty Quantification.Journal of imaging informatics in medicine · 2026Article
- A New Method Using Deep Learning to Predict the Response to Cardiac Resynchronization Therapy.Journal of imaging informatics in medicine · 2025Article
- Construction of a web-based dynamic nomogram for predicting the prognosis in acute heart failure.ESC heart failure · 2023Article
- A machine learning method integrating ECG and gated SPECT for cardiac resynchronization therapy decision support.European journal of nuclear medicine and molecular imaging · 2023Article
- Evaluation of dyssynchrony with nuclear cardiac imaging: New evidence for an old parameter.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2022Article
- Technical aspects of gated SPECT MPI assessment of left ventricular dyssynchrony used in the VISION-CRT study.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- A new method to recommend left ventricular lead positions for improved CRT volumetric response and long-term prognosis.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021Article
- Incremental Value of Left Ventricular Mechanical Dyssynchrony Assessment by Nitrogen-13 Ammonia ECG-Gated PET in Patients With Coronary Artery Disease.Frontiers in cardiovascular medicine · 2021Article
- Behind Traditional Semi-quantitative Scores of Myocardial Perfusion Imaging: An Eye on Niche Parameters.European cardiology · 2019Review
- Is it time for personalized cardiac resynchronization therapy.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Role of Gated Myocardial Glucose Metabolic Imaging in Assessing Left Ventricular Systolic Dyssynchrony after Myocardial Infarction and the Influential Factors.Scientific reports · 2018Article
Corrections and comments
- Commented on by
Authors and funding
9 authors at 3 institutions in 2 countries.
Funding
Abstract
objectivesThe purpose of this study is to use ECG-gated SPECT MPI to detect the latest contracting viable left ventricular (LV) segments to help guide the LV probe placement used in CRT therapy and to validate segment selection against the visual integration method by experts.
methodsFor each patient, the resting ECG-gated SPECT MPI short-axis images were sampled in 3D to generate a polar map of the perfusion distribution used to determine LV myocardial viability, and to measure LV synchronicity using our phase analysis tool. In the visual integration method, two experts visually interpreted the LV viability and mechanical dyssynchrony from the short-axis images and polar maps of viability and phase, to determine the latest contracting viable segments using the 17-segment model. In the automatic method, the apical segments, septal segments, and segments with more than 50% scar were excluded as these are not candidates for CRT LV probe placement. Amongst the remaining viable segments, the segments, whose phase angles were within 10° of the latest phase angle (the most delayed contracting segment), were identified for potential CRT LV probe placement and ranked based on the phase angles of the segments. Both methods were tested in 36 pre-CRT patients who underwent ECG-gated SPECT MPI. The accuracy was determined as the percent agreement between the visual integration and automatic methods. The automatic method was performed by a second independent operator to evaluate the inter-operator processing reproducibility.
resultsIn all the 36 patients, the LV lead positions of the 1st choices recommended by the automatic and visual integration methods were in the same segments in 35 patients, which achieved an agreement rate of 97.2%. In the inter-operator reproducibility test, the LV lead positions of the 1st choices recommended by the two operators were in the same segments in 25 patients, and were in the adjacent segments in 7 patients, which achieved an overall agreement of 88.8%.
conclusionsAn automatic method has been developed to detect the latest contracting viable LV segments to help guide the LV probe placement used in CRT therapy. The retrospective clinical study with 36 patients suggests that this method has high agreement against the visual integration method by experts and good inter-operator reproducibility. Consequently, this method is promising to be a clinical tool to recommend the CRT LV lead positions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials