Evidence map›Paper›PMID 28349184›Full record

ArticleCalcified tissue international2017

The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT.

M Peters, A Scharmga, A van Tubergen, J Arts, D Loeffen, R Weijers, B van Rietbergen, P Geusens, J P van den Bergh

Open access · hybridAbstract read
In one paragraph

Article in Calcified tissue international, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 15 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 3 countries.

M PetersDivision of Rheumatology, Department of Internal Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands. michiel.peters@maastrichtuniversity.nl.
A ScharmgaDivision of Rheumatology, Department of Internal Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands.
A van TubergenDivision of Rheumatology, Department of Internal Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands.
J ArtsDepartment of Orthopaedic Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
D LoeffenDepartment of Radiology, Maastricht University Medical Center, Maastricht, The Netherlands.
R WeijersDepartment of Radiology, Maastricht University Medical Center, Maastricht, The Netherlands.
B van RietbergenDepartment of Orthopaedic Surgery, Maastricht University Medical Center, Maastricht, The Netherlands.
P GeusensDivision of Rheumatology, Department of Internal Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands.
J P van den BerghDivision of Rheumatology, Department of Internal Medicine, Maastricht University Medical Center, P.O. Box 5800, 6202 AZ, Maastricht, The Netherlands.
Maastricht University · NLUniversity Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We developed a semi-automated algorithm for the detection of cortical interruptions in finger joints using high-resolution peripheral quantitative computed tomography (HR-pQCT). Here, we tested its reliability compared to microCT (µCT) as gold standard. Nineteen joints of 10 female anatomic index fingers were imaged by HR-pQCT and µCT (82 and 18 µm isotropic voxel sizes, respectively). The algorithm was applied for detection of cortical interruptions of different minimum diameters (range >0.16 to >0.50 mm). Reliability was tested at the joint level with intra-class correlation coefficient (ICC) for the number of interruptions and interruption surface, and at the level of a single interruption for matching between HR-pQCT and µCT with a fixed interruption diameter (>0.10 mm) on µCT. The positive predictive value (PPV

Indexed as

AlgorithmsTomography, X-Ray ComputedX-Ray MicrotomographyAgedAged, 80 and overArthritis, RheumatoidAutomationEvaluation Studies as TopicFemaleFinger JointHumansReproducibility of ResultsCortical interruptionsFinger jointsHigh resolution peripheral quantitative computed tomographyMicro computed tomographyRheumatoid arthritis

Identifiers

PMID28349184
PMCPMC5498594
OpenAlexW2598076426

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.