ReviewIndian journal of ophthalmology2017
Intraoperative optical coherence tomography in anterior segment surgeries.
Review in Indian journal of ophthalmology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 25 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
25 citing papers in PubMed, 46 citations in OpenAlex.
- Anterior segment optical coherence tomography-guided assessment of wound healing after cyanoacrylate glue patch for corneal perforations.Indian journal of ophthalmology · 2026Article
- Clinical Applications of Anterior Segment Optical Coherence Tomography in Managing Phakic and Secondary Intraocular Lens Implants: A Comprehensive Review.Diagnostics (Basel, Switzerland) · 2025Review
- Expanding Application of Optical Coherence Tomography Beyond the Clinic: A Narrative Review.Diagnostics (Basel, Switzerland) · 2025Review
- Emerging Applications of Intraoperative Optical Coherence Tomography in Corneal Surgery: A Narrative Review.Journal of clinical medicine · 2024Review
- Intra-operative optical coherence tomography in corneal lamellar graft reinforcement for Boston type I keratoprosthesis corneal melt.Indian journal of ophthalmology · 2023Article
- Microscope integrated OCT (Mi-OCT) guided retrieval of intrastromal corneal foreign body.GMS ophthalmology cases · 2023Article
- Evolution of manual small-incision cataract surgery from 8 mm to 2 mm - A comprehensive review.Indian journal of ophthalmology · 2022Review
- Intraoperative Anterior Segment Optical Coherence Tomography in the Management of Cataract Surgery: State of the Art.Journal of clinical medicine · 2022Review
- An Overview of Intraoperative OCT-Assisted Lamellar Corneal Transplants: A Game Changer?Diagnostics (Basel, Switzerland) · 2022Review
- Intraoperative optical coherence tomography (I-OCT) assisted passage of the encircling element during retinal detachment surgery.GMS ophthalmology cases · 2022Article
- Update on imaging modalities for ocular surface pathologies.Current ophthalmology reports · 2021Article
- Study 3: Assessment of events during surgery on posterior polar cataracts using intraoperative optical coherence tomography.Indian journal of ophthalmology · 2021Article
- High resolution anterior segment optical coherence tomography of ocular surface lesions: A review and handbook.Expert review of ophthalmology · 2021Article
- Intraoperative Optical Coherence Tomography Imaging in Corneal Surgery: A Literature Review and Proposal of Novel Applications.Journal of ophthalmology · 2020Article
- Intraoperative Optical Coherence Tomography Analysis of Clear Corneal Incision: Effect of the Lateral Stromal Hydration.Journal of ophthalmology · 2020Article
- Intraoperative Optical Coherence Tomography Guided Ocular Surgeries: Critical Analysis of Clinical Role and Future Perspectives.Clinical ophthalmology (Auckland, N.Z.) · 2020Review
- Intra-operative ASOCT determined changes in angle recess in plateau iris syndrome post phaco alone and post phaco-endocycloplasty.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2019Article
- 'Acute-angled bevel' sign to assess donor lenticule orientation in ultra-thin descemet stripping automated endothelial keratoplasty.BMJ case reports · 2019Review
- Intraoperative optical coherence tomography-guided scleral suture passage while performing surgery on extraocular muscles.Indian journal of ophthalmology · 2018Article
- Intraoperative assessment of corneal injuries using microscope-integrated optical coherence tomography.Indian journal of ophthalmology · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Intraoperative optical coherence tomography (iOCT) is a noninvasive imaging modality that provides a real-time dynamic feedback of the various surgical steps. Comprehensive literature search was performed in MEDLINE using "intraoperative optical coherence tomography" and "iOCT" as keywords. The use of iOCT as an aid to decision-making has been successfully reported in cases undergoing keratoplasty, implantable Collamer lens (ICL) implantation as well as cataract surgery. iOCT helps to assess the graft-host relationship in penetrating keratoplasty. It helps confirm the presence of a big bubble, detect subclinical big bubbles and guide layer by layer stromal dissection in cases of deep anterior lamellar keratoplasty. It acts as a guide during crucial surgical steps in endothelial keratoplasty, right from scoring of the Descemet membrane to ensuring graft apposition at the end of surgery. The morphological features of the corneal incision in phacoemulsification may be assessed. iOCT is a useful tool in assessing the status of the posterior capsule and may help identify preexisting posterior capsular defects during cataract surgery in various clinical scenarios such as posterior polar cataract, traumatic cataract, and vitrectomized eyes. It allows on-table assessment of the ICL vault and potentially facilitates exchange of ICL in the same sitting in extremes of vault. Ocular surface disorders such as ocular surface squamous neoplasia, pterygium, and dermoid may find an application for iOCT, wherein an iOCT-guided stromal dissection will ensure adequate depth of dissection. Further technological advancements may allow for automatic centration and tracking and address the present limitation of instrument-induced shadowing.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.