Evidence map›Paper›PMID 28340588›Full record

ArticleBiomedical engineering online2017

Comparison of the COM-FCP inclination angle and other mediolateral stability indicators for turning.

Rui Xu, Xin Wang, Jiajia Yang, Feng He, Xin Zhao, Hongzhi Qi, Peng Zhou, Dong Ming

Abstract readComparative Study
In one paragraph

Article in Biomedical engineering online, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Rui XuDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Xin WangDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Jiajia YangDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Feng HeDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Xin ZhaoDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Hongzhi QiDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Peng ZhouDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China.
Dong MingDepartment of Biomedical Engineering, College of Precision Instruments and Optoelectronics Engineering, Tianjin University, Tianjin, China. richardming@tju.edu.cn.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStudies have shown that turning is associated with more instability than straight walking and instability increases with turning angles. However, the precise relationship of changes in stability with the curvature and step length of turning is not clear. The traditional center of mass (COM)-center of pressure (COP) inclination angle requires the use of force plates. A COM-foot contact point (FCP) inclination angle derived from kinematic data is proposed in this study as a measure of the stability of turning.

methodsIn order to generate different degrees of stability, we designed an experiment of walking with different curvatures and step lengths. Simultaneously, a novel method was proposed to calculate the COM-FCP inclination angles of different walking trajectories with different step lengths for 10 healthy subjects. The COM-FCP inclination angle, the COM acceleration, the step width and the COM-ankle inclination angles were statistically analyzed.

resultsThe statistical results showed that the mediolateral (ML) COM-FCP inclination angles increased significantly as the curvature of the walking trajectories or the step length in circular walking increased. Changes in the ML COM acceleration, the step width and the ML COM-ankle inclination angle verified the feasibility and reliability of the proposed method. Additionally, the ML COM-FCP inclination angle was more sensitive to the ML stability than the ML COM-ankle inclination angle.

conclusionsThe work suggests that it is more difficult to keep balance when walking in a circular trajectory with a larger curvature or in a larger step length. Essentially, turning with a larger angle in one step leads to a lower ML stability. A novel COM-FCP inclination angle was validated to indicate ML stability. This method can be applied to complicated walking tasks, where the force plate is not applicable, and it accounts for the variability of the base of support (BOS) compared to the COM-ankle inclination angle.

Indexed as

Mechanical PhenomenaPressureWalkingAccelerationBiomechanical PhenomenaFemaleHumansMaleModels, BiologicalYoung AdultCircular walkingCurvatureMediolateral inclination angleMediolateral stabilityStep length

Identifiers

PMID28340588
PMCPMC5364651

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.