Evidence map›Paper›PMID 28340223›Full record

ArticleEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2017

Implantation of cardiac resynchronization therapy devices using three leads by cephalic vein dissection approach.

Alexios Hadjis, Riccardo Proietti, Vidal Essebag

Abstract read
In one paragraph

Article in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. EHRA expert consensus statement and practical guide on optimal implantation technique for conventional pacemakers and implantable cardioverter-defibrillators: endorsed by the Heart Rhythm Society (HRS), the Asia Pacific Heart Rhythm Society (APHRS), and the Latin-American Heart Rhythm Society (LAHRS).Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2021
    Article
  8. Article
  9. Article
  10. Complications of electrotherapy - the dark side of treatment with cardiac implantable electronic devices.Postepy w kardiologii interwencyjnej = Advances in interventional cardiology · 2018
    Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Alexios HadjisMcGill University Health Centre, 1650 Cedar Avenue, Room E5-200, Montreal, Quebec H3G 1A4, Canada.
Riccardo ProiettiCardiology Department, Luigi Sacco Hospital, Milan, Italy.
Vidal EssebagMcGill University Health Centre, 1650 Cedar Avenue, Room E5-200, Montreal, Quebec H3G 1A4, Canada.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsPercutaneous subclavian, axillary, and cephalic vein access are all used in conjunction for atrial and ventricular lead implantation, though no standard approach for cardiac resynchronization therapy (CRT) device implantation has been established. We describe an effective and a safe technique for implanting three leads via cephalic vein for CRT pacemaker and/or defibrillator implantations. METHODS AND

resultsA total of 171 consecutive patients undergoing de novo implantation of CRT pacemaker or defibrillator were included. Cephalic vein access was achieved by dissection and direct visualization. If the cephalic vein was inadequate, alternate means of access was determined after outset of the procedure. Procedural success rates and complications were recorded. Of the 171 de novo CRT implant attempts, 169 (98.8%) patients had successful implantation of all 3 leads on the first attempt. Of the 171 procedural attempts, 150 (87.7%) patients had all 3 leads placed via cephalic vein. Overall, complications occurred in 6 of 171 patients (3.5%) including initial and repeat procedures. These complications included seven lead dislodgements, two cases of diaphragmatic stimulation requiring lead revision, and one coronary sinus dissection without pericardial effusion. There were no cases of pneumothorax, pocket haematoma requiring evacuation, or infection.

conclusionThe triple lead via cephalic vein technique is safe and effective when used as a first approach for CRT device implantation.

Indexed as

Cardiac Resynchronization TherapyCardiac Resynchronization Therapy DevicesDefibrillators, ImplantableDissectionAgedAged, 80 and overCatheterization, PeripheralElectric CountershockFeasibility StudiesFemaleHumansMaleMiddle AgedProsthesis DesignProsthesis ImplantationTreatment OutcomeBiventricular pacingCardiac resynchronization therapyCephalic veinDefibrillatorPacemakerTechniques

Identifiers

PMID28340223
PMCPMC5834013

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.