Evidence map›Paper›PMID 28340005›Full record

SynthesisEuropace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology2017

Inappropriate shocks in single-chamber and subcutaneous implantable cardioverter-defibrillators: a systematic review and meta-analysis.

Angelo Auricchio, J Harrison Hudnall, Edward J Schloss, Laurence D Sterns, Takashi Kurita, Albert Meijer, Dedra H Fagan, Tyson Rogers

Registry-linked trialAbstract readMeta-AnalysisSystematic Review
In one paragraph

Synthesis in Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04344704 (Prevention of Inappropriate Therapies and Serious Adverse Cardiac and Cerebrovascular Events With a Single Chamber Implantable Cardioverter Defibrillator), which is not on this map. Cited by 19 papers, 3 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
19citing papers in PubMed, 3 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04344704 unknown statusnot on this mapstarted 2018, after this paper: background citation

Prevention of Inappropriate Therapies and Serious Adverse Cardiac and Cerebrovascular Events With a Single Chamber Implantable Cardioverter Defibrillator (ICD) With DX Floating Dipole Detection. PREVENT DX

Typeobservational_patient_registrySponsorTrialance SCCLRan2018 to 2023Enrolled462ConditionsPrevention of Inappropriate Therapies and MACCE. Single-chamber ICDArmsSingle chamber DAI device with floating atrial dipole
3 · Its place in the literature

Who cites it

19 citing papers in PubMed, 3 syntheses or guidelines pooled it.

  1. Pooled it
  2. Comparing the safety of subcutaneous versus transvenous ICDs: a meta-analysis.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2021
    Pooled it
  3. Pooled it
  4. Trial
  5. Trial
  6. Review
  7. Incidence and risk factors for first and recurrent ICD shock therapy in patients with an implantable cardioverter defibrillator.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2025
    Article
  8. Occurrence of premature battery depletion in a large multicentre registry of subcutaneous cardioverter-defibrillator patients.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
  9. Incidence, implications, and management of sense-B-noise failure in subcutaneous cardioverter-defibrillator patients: insights from a large multicentre registry.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2024
    Article
  10. Modern subcutaneous implantable defibrillator therapy in patients with cardiomyopathies and channelopathies: data from a large multicentre registry.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  11. Low rates of inappropriate shocks in contemporary real-world implantable cardioverter defibrillator patients: the CARAT observational study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Observational
  12. Clinical course of hypertrophic cardiomyopathy patients implanted with a transvenous or subcutaneous defibrillator.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  13. Review
  14. Reduction in inappropriate therapies through device programming in subcutaneous implantable defibrillator patients: data from clinical practice.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2023
    Article
  15. Article
  16. Impact of SMART Pass filter in patients with ajmaline-induced Brugada syndrome and subcutaneous implantable cardioverter-defibrillator eligibility failure: results from a prospective multicentre study.Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology · 2022
    Article
  17. Article
  18. Article
  19. Optimal Strategies to Reduce Inappropriate Implantable Cardioverter-defibrillator Shocks.The Journal of innovations in cardiac rhythm management · 2019
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Angelo AuricchioDivision of Cardiology, Fondazione Cardiocentro Ticino, Via Tesserete, 48, CH-6900 Lugano, Switzerland.
J Harrison HudnallMedtronic, PLC, Mounds View, MN, USA.
Edward J SchlossThe Christ Hospital/The Ohio Heart & Vascular Center, Cincinnati, OH, USA.
Laurence D SternsRoyal Jubilee Hospital, Victoria, BC, Canada.
Takashi KuritaDivision of Cardiology, Kinki University School of Medicine, Osaka, Japan.
Albert MeijerCatharina Ziekenhuis, Eindhoven, The Netherlands.
Dedra H FaganMedtronic, PLC, Mounds View, MN, USA.
Tyson RogersNAMSA, Inc., Minneapolis, MN, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

aimsSingle-chamber (VR-ICD) and subcutaneous (S-ICD) implantable cardioverter-defibrillators are effective to protect patients against sudden death but expose them to higher risk of inappropriate shock (IS). We sought to quantify the annual rate and influencing factors of ISs in VR- and S-ICDs from the literature. METHODS AND

resultsPubMed, Embase, and Cochrane Library were searched for full text articles with IS rates. Poisson distribution estimated proportion of patients with ISs; rates were annualized based on follow-up duration. Random effects meta-analysis accounted for study-to-study variation. Out of 3264 articles, 16 qualified for the meta-analysis. Across studies, 6.4% [95% confidence interval (CI) 5.1-7.9%] of patients received an IS per year. Meta-regression analyses demonstrated that IS rates were lower in more recent studies [rate ratio (RR) per year: 0.93, 95% CI: 0.87-0.98; P = 0.01] and trended lower in studies with longer follow-up (RR per year: 0.78, 95% CI: 0.60-1.01; P = 0.06). Use of S-ICDs (RR: 1.81, 95% CI: 0.86-3.81; P = 0.12) and ventricular tachycardia zone programmed on (RR: 1.13, 95% CI: 0.65-1.97; P = 0.66) were not associated with a significantly increased change in risk. The IS rate observed in one of the more recent studies was significantly lower than predicted after accounting for covariates (RR: 0.29, 95% CI: 0.14-0.60; P < 0.001).

conclusionsA comprehensive review of the literature shows that 6.4% of patients with ICDs experienced their first IS annually. One of the 16 studies was better than predicted with the lowest reported rate (1.9%) and could not be explained by timing of the study or other covariates.

Indexed as

Prosthesis FailureArrhythmias, CardiacDeath, Sudden, CardiacDefibrillators, ImplantableElectric CountershockElectric StimulationHumansOdds RatioProsthesis DesignRisk AssessmentRisk FactorsTime FactorsTreatment OutcomeImplantable cardioverter-defibrillatorInappropriate shocksMeta-analysisSubcutaneous ICDSudden cardiac death

Identifiers

PMID28340005
PMCPMC5834016

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.