ArticlePhysics in medicine and biology2017
Motion compensation in extremity cone-beam CT using a penalized image sharpness criterion.
Article in Physics in medicine and biology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 27 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
27 citing papers in PubMed, 1 synthesis or guideline pooled it, 73 citations in OpenAlex.
- High-Resolution Peripheral Quantitative Computed Tomography for Bone Evaluation in Inflammatory Rheumatic Disease.Frontiers in medicine · 2020Pooled it
- Differentiable Forward and Back-Projector for Rigid Motion Estimation in X-Ray Imaging.IEEE transactions on bio-medical engineering · 2026Article
- [Motion parameter decoupling and motion constraint-driven optimization for correcting rigid motion artifacts in cone-beam computed tomography].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2026Article
- Joint Cone-Beam CT Reconstruction and Rigid Motion Compensation Using A Differentiable Projector.Proceedings of SPIE--the International Society for Optical Engineering · 2026Article
- Motion correction in CBCT imaging using gate-less model-based reconstruction of non-rigid motion and images.Medical physics · 2025Article
- [A segmented backprojection tensor degradation feature encoding model for motion artifacts correction in dental cone beam computed tomography].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2025Article
- Vessel-targeted compensation of deformable motion in interventional cone-beam CT.Medical image analysis · 2024Article
- Systematic Review on Learning-based Spectral CT.ArXiv · 2024Article
- [A deep blur learning-based motion artifact reduction algorithm for dental cone-beam computed tomography images].Nan fang yi ke da xue xue bao = Journal of Southern Medical University · 2024Article
- Deformable motion compensation in interventional cone-beam CT with a context-aware learned autofocus metric.Medical physics · 2024Article
- Systematic Review on Learning-based Spectral CT.IEEE transactions on radiation and plasma medical sciences · 2024Article
- Reference-free learning-based similarity metric for motion compensation in cone-beam CT.Physics in medicine and biology · 2022Article
- Context-Aware, Reference-Free Local Motion Metric for CBCT Deformable Motion Compensation.Proceedings of SPIE--the International Society for Optical Engineering · 2022Article
- Rigid and Non-Rigid Motion Compensation in Weight-Bearing CBCT of the Knee Using Simulated Inertial Measurements.IEEE transactions on bio-medical engineering · 2022Article
- Sinogram + image domain neural network approach for metal artifact reduction in low-dose cone-beam computed tomography.Journal of medical imaging (Bellingham, Wash.) · 2021Article
- Deformable motion compensation for interventional cone-beam CT.Physics in medicine and biology · 2021Article
- Computed Tomography- (CT-) Based Virtual Surgery Planning for Spinal Intervertebral Foraminal Assisted Clinical Treatment.Journal of healthcare engineering · 2021Article
- Cone-beam CT for imaging of the head/brain: Development and assessment of scanner prototype and reconstruction algorithms.Medical physics · 2020Article
- Multi-Modal Imaging to Assess the Interaction Between Inflammation and Bone Damage Progression in Inflammatory Arthritis.Frontiers in medicine · 2020Article
- Motion compensation in extremity cone-beam computed tomography.Skeletal radiology · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
Cone-beam CT (CBCT) for musculoskeletal imaging would benefit from a method to reduce the effects of involuntary patient motion. In particular, the continuing improvement in spatial resolution of CBCT may enable tasks such as quantitative assessment of bone microarchitecture (0.1 mm-0.2 mm detail size), where even subtle, sub-mm motion blur might be detrimental. We propose a purely image based motion compensation method that requires no fiducials, tracking hardware or prior images. A statistical optimization algorithm (CMA-ES) is used to estimate a motion trajectory that optimizes an objective function consisting of an image sharpness criterion augmented by a regularization term that encourages smooth motion trajectories. The objective function is evaluated using a volume of interest (VOI, e.g. a single bone and surrounding area) where the motion can be assumed to be rigid. More complex motions can be addressed by using multiple VOIs. Gradient variance was found to be a suitable sharpness metric for this application. The performance of the compensation algorithm was evaluated in simulated and experimental CBCT data, and in a clinical dataset. Motion-induced artifacts and blurring were significantly reduced across a broad range of motion amplitudes, from 0.5 mm to 10 mm. Structure similarity index (SSIM) against a static volume was used in the simulation studies to quantify the performance of the motion compensation. In studies with translational motion, the SSIM improved from 0.86 before compensation to 0.97 after compensation for 0.5 mm motion, from 0.8 to 0.94 for 2 mm motion and from 0.52 to 0.87 for 10 mm motion (~70% increase). Similar reduction of artifacts was observed in a benchtop experiment with controlled translational motion of an anthropomorphic hand phantom, where SSIM (against a reconstruction of a static phantom) improved from 0.3 to 0.8 for 10 mm motion. Application to a clinical dataset of a lower extremity showed dramatic reduction of streaks and improvement in delineation of tissue boundaries and trabecular structures throughout the whole volume. The proposed method will support new applications of extremity CBCT in areas where patient motion may not be sufficiently managed by immobilization, such as imaging under load and quantitative assessment of subchondral bone architecture.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.