Evidence map›Paper›PMID 28327093›Full record

Trial reportBMC anesthesiology2017

Continuous Non-invasive finger cuff CareTaker® comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery.

Irwin Gratz, Edward Deal, Francis Spitz, Martin Baruch, I Elaine Allen, Julia E Seaman, Erin Pukenas, Smith Jean

2 registry-linked trialsAbstract readClinical TrialComparative Study
In one paragraph

Trial report in BMC anesthesiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 30 papers.

0numbers the graph read from it
0cells of the map it votes in
30citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT04817137 nacompletednot on this mapstarted 2021, after this paper: background citation

Validation of a Novel Non-invasive Continuous Blood Pressure Monitor in Children Ages 2- 17 Years-old

TypeinterventionalSponsorBoston Children's HospitalRan2021 to 2023Enrolled35ConditionsBlood PressureArmsCareTaker PDA Device
NCT05105204 unknown statusnot on this mapstarted 2021, after this paper: background citation

ArteVu Blood Pressure Accuracy Study

Typeobservational_patient_registrySponsorCardio Ring Technologies, Inc. Taiwan BranchRan2021 to 2022Enrolled50ConditionsBlood PressureArmsArteVu
3 · Its place in the literature

Who cites it

30 citing papers in PubMed.

  1. D-dimer in Marfan syndrome: effect of obstructive sleep apnea induced blood pressure surges.American journal of physiology. Heart and circulatory physiology · 2022
    Trial
  2. Article
  3. Article
  4. Observational
  5. Article
  6. Review
  7. Article
  8. Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of clinical monitoring and computing · 2024
    Review
  9. Article
  10. Article
  11. Article
  12. Review
  13. Article
  14. Review
  15. Article
  16. Observational
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Irwin GratzDepartment of Anesthesiology, Cooper Medical School at Rowan University Cooper University Hospital, Camden, New Jersey, USA.
Edward DealDepartment of Anesthesiology, Cooper Medical School at Rowan University Cooper University Hospital, Camden, New Jersey, USA.
Francis SpitzDepartment of Anesthesiology, Cooper Medical School at Rowan University Cooper University Hospital, Camden, New Jersey, USA.
Martin BaruchEmpirical Technologies Corporation, Charlottesville, Virginia, USA.
I Elaine AllenDepartment of Biostatistics and Epidemiology, University of California, San Francisco, CA, USA.
Julia E SeamanDepartment of Pharmaceutical Chemistry, University of California, San Francisco, California, USA.
Erin PukenasDepartment of Anesthesiology, Cooper Medical School at Rowan University Cooper University Hospital, Camden, New Jersey, USA.
Smith JeanDepartment of Anesthesiology, Cooper Medical School at Rowan University Cooper University Hospital, Camden, New Jersey, USA. Jean@rowan.edu.

Funding

PHARMACEUTICAL SCIENCES AND PHARMACOGENOMICST32GM007175 · NIGMS · UNIVERSITY OF CALIFORNIA, SAN FRANCISCO · PI AHITUV, NADAV, KROETZ, DEANNA L · 1985 to 2021
$7.1M
NIGMS NIH HHS T32 GM007175
6 · The paper itself

Abstract

backgroundDespite increased interest in non-invasive arterial pressure monitoring, the majority of commercially available technologies have failed to satisfy the limits established for the validation of automatic arterial pressure monitoring by the Association for the Advancement of Medical Instrumentation (AAMI). According to the ANSI/AAMI/ISO 81060-2:2013 standards, the group-average accuracy and precision are defined as acceptable if bias is not greater than 5 mmHg and standard deviation is not greater than 8 mmHg. In this study, these standards are used to evaluate the CareTaker® (CT) device, a device measuring continuous non-invasive blood pressure via a pulse contour algorithm called Pulse Decomposition Analysis.

methodsA convenience sample of 24 patients scheduled for major abdominal surgery were consented to participate in this IRB approved pilot study. Each patient was monitored with a radial arterial catheter and CT using a finger cuff applied to the contralateral thumb. Hemodynamic variables were measured and analyzed from both devices for the first thirty minutes of the surgical procedure including the induction of anesthesia. The mean arterial pressure (MAP), systolic and diastolic blood pressures continuously collected from the arterial catheter and CT were compared. Pearson correlation coefficients were calculated between arterial catheter and CT blood pressure measurements, a Bland-Altman analysis, and polar and 4Q plots were created.

resultsThe correlation of systolic, diastolic, and mean arterial pressures were 0.92, 0.86, 0.91, respectively (p < 0.0001 for all the comparisons). The Bland-Altman comparison yielded a bias (as measured by overall mean difference) of -0.57, -2.52, 1.01 mmHg for systolic, diastolic, and mean arterial pressures, respectively with a standard deviation of 7.34, 6.47, 5.33 mmHg for systolic, diastolic, and mean arterial pressures, respectively (p < 0.001 for all comparisons). The polar plot indicates little bias between the two methods (90%/95% CI at 31.5°/52°, respectively, overall bias = 1.5°) with only a small percentage of points outside these lines. The 4Q plot indicates good concordance and no bias between the methods.

conclusionsIn this study, blood pressure measured using the non-invasive CT device was shown to correlate well with the arterial catheter measurements. Larger studies are needed to confirm these results in more varied settings. Most patients exhibited very good agreement between methods. Results were well within the limits established for the validation of automatic arterial pressure monitoring by the AAMI.

Indexed as

AgedAged, 80 and overArterial PressureBlood Pressure DeterminationFemaleHumansMaleMiddle AgedMonitoring, IntraoperativePilot ProjectsCareTakerCentral blood pressureFinger cuffIntra-Arterial pressureNon-Invasive

Identifiers

PMID28327093
PMCPMC5361833

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.