Trial reportBMC anesthesiology2017
Continuous Non-invasive finger cuff CareTaker® comparable to invasive intra-arterial pressure in patients undergoing major intra-abdominal surgery.
Trial report in BMC anesthesiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 30 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Validation of a Novel Non-invasive Continuous Blood Pressure Monitor in Children Ages 2- 17 Years-old
ArteVu Blood Pressure Accuracy Study
Who cites it
30 citing papers in PubMed.
- D-dimer in Marfan syndrome: effect of obstructive sleep apnea induced blood pressure surges.American journal of physiology. Heart and circulatory physiology · 2022Trial
- Wearable, cuffless, and portable devices for blood pressure monitoring (2015-2025): a scoping review of technologies, calibration, clinical validation, and regulatory frameworks.Frontiers in digital health · 2026Article
- Blood pressure dynamic instability and neurodegeneration in older adults.Journal of Alzheimer's disease : JAD · 2025Article
- End-tidal CO2 changes as predictors of significant blood pressure variations during general anesthesia.BMC anesthesiology · 2025Observational
- Blunted Blood Pressure Dipping During Night Shift Work: Does It Matter? Can We Intervene?American journal of industrial medicine · 2025Article
- Cuffless Blood Pressure Monitor for Home and Hospital Use.Sensors (Basel, Switzerland) · 2025Review
- Reliability of beat-to-beat blood pressure variability in older adults.Scientific reports · 2024Article
- Haemodynamic monitoring during noncardiac surgery: past, present, and future.Journal of clinical monitoring and computing · 2024Review
- Reliability of beat-to-beat blood pressure variability in older adults.Research square · 2024Article
- Short-term blood pressure variability and brain functional network connectivity in older adults.Neuroimage. Reports · 2024Article
- Agreement between cardiac output estimation with a wireless, wearable pulse decomposition analysis device and continuous thermodilution in post cardiac surgery intensive care unit patients.Journal of clinical monitoring and computing · 2024Article
- The Promise and Illusion of Continuous, Cuffless Blood Pressure Monitoring.Current cardiology reports · 2023Review
- Estimating Blood Pressure during Exercise with a Cuffless Sphygmomanometer.Sensors (Basel, Switzerland) · 2023Article
- A Review of Skin-Wearable Sensors for Non-Invasive Health Monitoring Applications.Sensors (Basel, Switzerland) · 2023Review
- Upper-Arm Photoplethysmographic Sensor with One-Time Calibration for Long-Term Blood Pressure Monitoring.Biosensors · 2023Article
- Perioperative changes in fluid distribution and haemodynamics in acute high-risk abdominal surgery.Critical care (London, England) · 2023Observational
- Short-term blood pressure variability is inversely related to regional amplitude of low frequency fluctuations in older and younger adults.Aging brain · 2023Article
- Patent landscape review of non-invasive medical sensors for continuous monitoring of blood pressure and their validation in critical care practice.Frontiers in medicine · 2023Review
- Measurement of Vital Signs Using Lifelight Remote Photoplethysmography: Results of the VISION-D and VISION-V Observational Studies.JMIR formative research · 2022Article
- A pilot randomized controlled trial of supervised, at-home, self-administered transcutaneous auricular vagus nerve stimulation (taVNS) to manage long COVID symptoms.Bioelectronic medicine · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
backgroundDespite increased interest in non-invasive arterial pressure monitoring, the majority of commercially available technologies have failed to satisfy the limits established for the validation of automatic arterial pressure monitoring by the Association for the Advancement of Medical Instrumentation (AAMI). According to the ANSI/AAMI/ISO 81060-2:2013 standards, the group-average accuracy and precision are defined as acceptable if bias is not greater than 5 mmHg and standard deviation is not greater than 8 mmHg. In this study, these standards are used to evaluate the CareTaker® (CT) device, a device measuring continuous non-invasive blood pressure via a pulse contour algorithm called Pulse Decomposition Analysis.
methodsA convenience sample of 24 patients scheduled for major abdominal surgery were consented to participate in this IRB approved pilot study. Each patient was monitored with a radial arterial catheter and CT using a finger cuff applied to the contralateral thumb. Hemodynamic variables were measured and analyzed from both devices for the first thirty minutes of the surgical procedure including the induction of anesthesia. The mean arterial pressure (MAP), systolic and diastolic blood pressures continuously collected from the arterial catheter and CT were compared. Pearson correlation coefficients were calculated between arterial catheter and CT blood pressure measurements, a Bland-Altman analysis, and polar and 4Q plots were created.
resultsThe correlation of systolic, diastolic, and mean arterial pressures were 0.92, 0.86, 0.91, respectively (p < 0.0001 for all the comparisons). The Bland-Altman comparison yielded a bias (as measured by overall mean difference) of -0.57, -2.52, 1.01 mmHg for systolic, diastolic, and mean arterial pressures, respectively with a standard deviation of 7.34, 6.47, 5.33 mmHg for systolic, diastolic, and mean arterial pressures, respectively (p < 0.001 for all comparisons). The polar plot indicates little bias between the two methods (90%/95% CI at 31.5°/52°, respectively, overall bias = 1.5°) with only a small percentage of points outside these lines. The 4Q plot indicates good concordance and no bias between the methods.
conclusionsIn this study, blood pressure measured using the non-invasive CT device was shown to correlate well with the arterial catheter measurements. Larger studies are needed to confirm these results in more varied settings. Most patients exhibited very good agreement between methods. Results were well within the limits established for the validation of automatic arterial pressure monitoring by the AAMI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.