Evidence map›Paper›PMID 28326426›Full record

ArticleArthroplasty today2016

Use of locking plates for fixation of the greater trochanter in patients with hip replacement.

Allison K Tetreault, Brian J McGrory

Open access · goldAbstract read
In one paragraph

Article in Arthroplasty today, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 27 citations in OpenAlex.

  1. Article
  2. From bench to bedside: a novel suture-augmented prosthesis for greater trochanteric fixation in osteoporotic hip arthroplasty.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2026
    Article
  3. Article
  4. Article
  5. [Research progress on treatment of unstable intertrochanteric fractures in elderly patients with bone cement type femoral head replacement].Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery · 2024
    Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Triple Surgical Fixation Technique for an Isolated Greater Trochanter Fracture in an Amateur Weightlifter.Journal of the American Academy of Orthopaedic Surgeons. Global research & reviews · 2022
    Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 2 institutions in 1 country.

Allison K TetreaultMaine Joint Replacement Institute, Portland, ME, USA; Tufts University School of Medicine, Boston, MA, USA.
Brian J McGroryMaine Joint Replacement Institute, Portland, ME, USA; Tufts University School of Medicine, Boston, MA, USA.
Joint Replacement Institute · USTufts University · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFixation of the greater trochanter with total hip replacement is challenging and associated with short- and long-term complications. Locking plate technology has been used for fixation of other bones and may be applied successfully in trochanteric fixation. The purpose of this retrospective study was to analyze the utility of the use of trochanteric locking plates in total hip arthroplasty (THA) patients.

methodsFrom 2004 to 2014, 32 procedures were performed to fix the greater trochanter in patients with trochanteric fracture, osteotomy, or nonunion in the setting of THA. The median age at the time of surgery was 69 years. This was a primary arthroplasty in 8 of the patients, conversion from prior hip surgery in 5, and a revision in 19. The greater trochanter was fixed with locking plate alone in 15 hips and with the addition of a single cerclage cable in 17 hips. Patients were followed clinically and radiographically until healing occurred. The median duration of radiographic follow-up was 41.6 months (range: 10-112 months).

resultsOsseous union occurred in 29 (90.6%) of 32 hips. The median Harris hip score was 94 (range 54-100, standard deviation = 10.4) at latest follow-up. Complications included broken hardware in 5 (15.6%) patients, of which 3 underwent subsequent hardware removal. Two additional patients elected hardware removal due to trochanteric pain.

conclusionsLocking plate technology is a successful method of fixation of the greater trochanter in patients with THA. Postoperative trochanteric pain and reoperation for hardware-related issues remain a challenge.

Indexed as

Internal fixationLocking plateTotal hip replacement (THA)Trochanteric fractureTrochanteric nonunionTrochanteric osteotomy

Identifiers

PMID28326426
PMCPMC5247560
OpenAlexW2530249261

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.