ArticleJournal of pediatric orthopedics2017
Measurement of Femoral Version by MRI is as Reliable and Reproducible as CT in Children and Adolescents With Hip Disorders.
Article in Journal of pediatric orthopedics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 29 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
29 citing papers in PubMed, 4 syntheses or guidelines pooled it.
- Association of femoral retroversion and out-toeing gait with development of hip osteoarthritis and treatment: a systematic review.Acta orthopaedica · 2025Pooled it
- Validity and reliability of ultrasonographic assessment of femoral and tibial torsion in children and adolescents: a systematic review.European journal of pediatrics · 2024Pooled it
- Over one third of patients with symptomatic femoroacetabular impingement display femoral or acetabular version abnormalities.Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA · 2021Pooled it
- Best Practices: Hip Femoroacetabular Impingement.AJR. American journal of roentgenology · 2021Pooled it
- The Modified Budin View: A Reliable and Accessible Screening Tool for Femoral Version Deformities in Joint-Preserving Hip Surgery.The American journal of sports medicine · 2026Article
- Reliability of fast T1 VIBE Dixon MRI for femoral version measurement in FAI patients: A comparative study with CT.European journal of radiology open · 2026Article
- Rotational Gait Problems in the Presence of Femoral Deformity.Bioengineering (Basel, Switzerland) · 2025Article
- Indications for Acetabular and Femoral Osteotomies for the Non-Arthritic Hip.Current reviews in musculoskeletal medicine · 2025Review
- Normal range of femoral version for different measurement methods on CT or MRI-scoping review of normal femoral version.Journal of hip preservation surgery · 2025Article
- The Bimalleolar Method Shows the Most Reliable Results for Measuring Tibial Torsion in Rotational MRI.Journal of clinical medicine · 2025Article
- Magnetic resonance imaging measurement of the femoral antetorsional angle: Comparison with computer tomography and clinical application in a diagnostic algorithm.Journal of experimental orthopaedics · 2025Article
- Femoral version and its clinical relevance in adult hip preservation surgery for developmental dysplasia of the hip.EFORT open reviews · 2024Review
- Quantifying radiation exposure in the radiological investigation of non-arthritic hip pain.Journal of hip preservation surgery · 2024Article
- Coxa valga and antetorta configuration leads to underestimation of the femoral component size: a matched case-control study of patients undergoing cementless total hip arthroplasty.Archives of orthopaedic and trauma surgery · 2024Article
- Morphometric and clinical comparison of MRI-based synthetic CT to conventional CT of the hip in children.Pediatric radiology · 2024Article
- [Preoperative MR imaging for hip dysplasia : Assessment of associated deformities and intraarticular pathologies].Orthopadie (Heidelberg, Germany) · 2023Review
- Assessment of femoral retroversion on preoperative hip magnetic resonance imaging in patients with slipped capital femoral epiphysis: Theoretical implications for hip impingement risk estimation.Journal of children's orthopaedics · 2023Article
- Correlation of femoral version measurements between computed tomography and magnetic resonance imaging studies in patients presenting with a femoroacetabular impingement-related complaint.Journal of hip preservation surgery · 2022Article
- Rotational Osteotomy for Femoral Version/Tibial Torsion.Current reviews in musculoskeletal medicine · 2022Review
- External snapping hip syndrome is associated with an increased femoral offset.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundFemoral version measurement techniques based on magnetic resonance imaging (MRI) studies have been developed as an alternative to the high levels of ionizing radiation associated with computed tomography (CT)-based methods. Previous studies have not evaluated the reliability, repeatability, and accuracy of MRI-based femoral version measurements in an adolescent population.
methodsSubjects who underwent MRI and CT studies for clinical suspicion of hip pain secondary to hip dysplasia or femoroacetabular impingement between 2011 and 2013 were identified. Rapid sequence femoral version images were obtained from MRI Hip dGEMRIC and/or postarthrogram studies. Femoral version images were also obtained from bilateral CT lower extremity, without contrast, studies. Measurements were made by 1 fellowship-trained, pediatric hip preservation attending surgeon, 2 pediatric orthopaedic surgical fellows, and 1 fellowship-trained musculoskeletal radiologist on 2 separate occasions. Linear mixed models were used to estimate the reliability and repeatability associated with CT-based and MRI-based measurements (intraclass correlation coefficients) and to estimate the agreement (CT-MRI) between the 2 techniques.
resultsThe mean age of 36 subjects was 15.4 years (±4.1 y). Interrater reliability was 0.91 (95% CI, 0.86-0.95) for the CT technique compared with 0.90 (95% CI, 0.86-0.94) for the rapid sequence MRI technique. Intrarater reliability for the CT technique was 0.96 (95% CI, 0.91-0.98) compared with 0.95 (95% CI, 0.90-0.97) for the MRI technique. The agreement between the MRI-based and CT-based techniques (bias: 1.9 degrees, limits of agreement: -11.3 to 14.9 degrees) was similar to the agreement between consecutive MRI measurements (bias: 0.4 degrees, limits of agreement: -7.8 to 8.6 degrees) as well as consecutive CT measurements (bias: 0.5 degrees, limits of agreement: -8.8 to 9.9 degrees).
conclusionsThe interrater and intrarater reliability and repeatability estimates (intraclass correlation coefficient values) associated with both techniques was excellent (>0.90). Acquirement of axial images at the pelvis and knee during MRI for investigation of adolescents with hip pain allows for reliable measurement of femoral version. LEVEL OF EVIDENCE: Level II-diagnostic study.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.