Evidence map›Paper›PMID 28321908›Full record

ArticleMagnetic resonance in medicine2018

Reduced field of view single-shot spiral perfusion imaging.

Yang Yang, Li Zhao, Xiao Chen, Peter W Shaw, Jorge A Gonzalez, Frederick H Epstein, Craig H Meyer, Christopher M Kramer, Michael Salerno

Abstract read
In one paragraph

Article in Magnetic resonance in medicine, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors.

Yang YangDepartments of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA.
Li ZhaoDepartment of Radiology, Beth Israel Deaconess Medical Center, Boston, Massachusetts, USA.
Xiao ChenMedical Imaging Technologies, Siemens Medical Solutions USA, Inc.
Peter W ShawCardiology Professional Services, Berkshire Medical Center, Pittsfield, Massachusetts, USA.
Jorge A GonzalezDivision of Cardiovascular Disease, Scripps Clinic, John R. Anderson V Medical Pavilion, La Jolla, California, USA.
Frederick H EpsteinDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Charlottesville, Virginia, USA.
Christopher M KramerDepartments of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA.
Michael SalernoDepartments of Medicine, Cardiovascular Division, University of Virginia Health System, Charlottesville, Virginia, USA.

Funding

MRI of Myocardial Function in Post-Infarct Knockout MiceR01EB001763 · NIBIB · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI EPSTEIN, FREDERICK H · 2003 to 2020
$5.4M
Training in Cardiovascular Imaging ResearchT32EB003841 · NIBIB · UNIVERSITY OF VIRGINIA CHARLOTTESVILLE · PI Jonathan R Lindner · 2004 to 2026
$4.4M
High-Resolution Whole Heart Quantitative CMR Perfusion Imaging in Ischemic Heart DiseaseR01HL131919 · NHLBI · UNIVERSITY OF VIRGINIA · PI ENNIS, DANIEL B · 2017 to 2021
$3.5M
Improved MR Techniques for Coronary Artery ImagingR01HL079110 · NHLBI · UNIVERSITY OF VIRGINIA · PI MEYER, CRAIG H · 2006 to 2010
$1.8M
Quantitative Adenosine Stress CMR with Spiral Pulse SequencesK23HL112910 · NHLBI · UNIVERSITY OF VIRGINIA · PI SALERNO, MICHAEL · 2012 to 2016
$789k
NHLBI NIH HHS K23 HL112910NHLBI NIH HHS R01 HL079110NHLBI NIH HHS R01 HL131919NIBIB NIH HHS R01 EB001763NIBIB NIH HHS T32 EB003841
6 · The paper itself

Abstract

purposeTo develop a single-shot spiral perfusion pulse sequence with outer-volume suppression (OVS) to achieve whole-heart coverage with a short temporal footprint of 10 ms per slice location.

methodsA highly accelerated single-shot variable density spiral pulse sequence with an integrated OVS module for reduced field of view (rFOV) perfusion imaging with 2 mm spatial resolution was developed and evaluated in simulations, phantom experiments and in clinical patients with (n = 8) or without (n = 8) OVS. Images were reconstructed by block low-rank sparsity with motion guidance (BLOSM) and graded by two cardiologists on a 5-point scale (1, excellent; 5, poor).

resultsSimulation and phantom results showed that OVS effectively suppressed the signal outside the desired field of view (FOV). Clinical patient data demonstrated high quality perfusion images with rFOV. The average image quality scores of full FOV cases and rFOV cases were 3.1 ± 0.64 and 2.3 ± 0.46, respectively, (P = 0.02) from cardiologist 1 and 2.5 ± 0.54 and 1.8 ± 0.47, respectively, (P = 0.04) from cardiologist 2, showing superior image quality for the rFOV images compared with the full FOV images.

conclusionA single-shot spiral perfusion sequence that uses OVS and BLOSM performs perfusion imaging with a very short temporal footprint per image supporting whole-heart coverage with good image quality. Magn Reson Med 79:208-216, 2018. © 2017 International Society for Magnetic Resonance in Medicine.

Indexed as

AlgorithmsAngina PectorisArtifactsCardiologyComputer SimulationHumansImage EnhancementImage Interpretation, Computer-AssistedImage Processing, Computer-AssistedModels, StatisticalMotionMyocardial Perfusion ImagingObserver VariationPerfusion ImagingPhantoms, Imagingfirst-pass perfusionouter-volume suppressionsingle-shotspiral trajectory

Identifiers

PMID28321908
PMCPMC5607067

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.