Evidence map›Paper›PMID 28319203›Full record

ArticlePloS one2017

Relationship between low tube voltage (70 kV) and the iodine delivery rate (IDR) in CT angiography: An experimental in-vivo study.

Michael M Lell, Ulrike Fleischmann, Hubertus Pietsch, Johannes G Korporaal, Ulrike Haberland, Andreas H Mahnken, Thomas G Flohr, Michael Uder, Gregor Jost

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 5 institutions in 2 countries.

Michael M LellDepartment of Radiology and Nuclear Medicine, Paracelsus Medical University, Nuernberg, Germany.ORCID http://orcid.org/0000-0002-4800-4428
Ulrike FleischmannDepartment of Radiology, Friedrich-Alexander University Erlangen, Erlangen, Germany.
Hubertus PietschMR and CT Contrast Media Research, Bayer Healthcare, Berlin, Germany.
Johannes G KorporaalSiemens Healthcare, Forchheim, Germany.
Ulrike HaberlandSiemens Healthcare, Forchheim, Germany.
Andreas H MahnkenDepartment of Radiology, University of Marburg, Marburg, Germany.
Thomas G FlohrSiemens Healthcare, Forchheim, Germany.
Michael UderDepartment of Radiology and Nuclear Medicine, Paracelsus Medical University, Nuernberg, Germany.
Gregor JostMR and CT Contrast Media Research, Bayer Healthcare, Berlin, Germany.
Siemens Healthineers (Germany) · DEBayer (United States) · USParacelsus Medizinische Privatuniversität · DEFriedrich-Alexander-Universität Erlangen-Nürnberg · DEPhilipps University of Marburg · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveVery short acquisition times and the use of low-kV protocols in CTA demand modifications in the contrast media (CM) injection regimen. The aim of this study was to optimize the use of CM delivery parameters in thoraco-abdominal CTA in a porcine model. MATERIALS AND

methodsSix pigs (55-68 kg) were examined with a dynamic CTA protocol (454 mm scan length, 2.5 s temporal resolution, 70 s total acquisition time). Four CM injection protocols were applied in a randomized order. 120 kV CTA protocol: (A) 300 mg iodine/kg bodyweight (bw), IDR = 1.5 g/s (flow = 5 mL/s), injection time (ti) 12 s (60 kg bw). 70 kV CTA protocols: 150 mg iodine/kg bw: (B) IDR = 0.75 g/s (flow = 2.5 mL/s), ti = 12 s (60 kg bw); (C) IDR = 1.5 g/s (flow = 5 mL/s), ti = 12 s (60 kg bw); (D) IDR = 3.0 g/s (flow = 10 mL/s), ti = 3 s (60 kg bw). The complete CM bolus shape was monitored by creating time attenuation curves (TAC) in different vascular territories. Based on the TAC, the time to peak (TTP) and the peak enhancement were determined. The diagnostic window (relative enhancement > 300 HU), was calculated and compared to visual inspection of the corresponding CTA data sets.

resultsThe average relative arterial peak enhancements after baseline correction were 358.6 HU (A), 356.6 HU (B), 464.0 HU (C), and 477.6 HU (D). The TTP decreased with increasing IDR and decreasing ti, protocols A and B did not differ significantly (systemic arteries, p = 0.843; pulmonary arteries, p = 0.183). The delay time for bolus tracking (trigger level 100 HU; target enhancement 300 HU) for single-phase CTA was comparable for protocol A and B (3.9, 4.3 s) and C and D (2.4, 2.0 s). The scan window time frame was comparable for the different protocols by visual inspection of the different CTA data sets and by analyzing the TAC.

conclusionsAll protocols provided sufficient arterial enhancement. The use of a 70 kV CTA protocol is recommended because of a 50% reduction of total CM volume and a 50% reduced flow rate while maintaining the bolus profile. In contrast to pulmonary arterial enhancement, the systemic arterial enhancement improved only slightly increasing the IDR from 1.5 g/s to 3 g/s because of bolus dispersion of the very short bolus (3s) in the lungs.

Indexed as

AnimalsComputed Tomography AngiographyContrast MediaFemaleIodineModels, AnimalSus scrofaTime FactorsContrast MediaIodine

Identifiers

PMID28319203
PMCPMC5358883
OpenAlexW2602176577

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked