Evidence map›Paper›PMID 28304201›Full record

ArticleInterventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences2017

Evaluation of the characteristics of various types of finishing coils for the embolization of intracranial aneurysms in an experimental model with radiolucent coils.

Keisuke Ota, Noriaki Matsubara, Shigeru Miyachi, Takashi Izumi, Masashi Ito, Takumi Asai, Takashi Yamanouchi, Toshihiko Wakabayashi

Abstract readEvaluation Study
In one paragraph

Article in Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Is a small coil more effective as a finishing coil for the embolization of intracranial aneurysms? Outcomes using GALAXY G3™ MINI micro-coils as finishing coils in a single center.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2021
    Article
  5. Article
  6. Experimental study of the characteristics of various types of filling coils for intracranial aneurysm embolisation.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Keisuke Ota1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Noriaki Matsubara1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Shigeru Miyachi1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Takashi Izumi1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Masashi Ito1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Takumi Asai1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Takashi Yamanouchi1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.
Toshihiko Wakabayashi1 Department of Neurosurgery, Nagoya University Graduate School of Medicine, Aichi, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In endovascular coil embolization of intracranial aneurysms, very soft coils, often called "finishing coils," are usually selected in the final stage of coil embolization. The authors developed a radiolucent coil made of thin nylon thread to evaluate the performance of coils under a situation simulating the course of embolization. The characteristics of various types of finishing coils were investigated using radiolucent coils. Experimental embolization was performed with a silicone aneurysm filled with radiolucent coils simulating the final stage of embolization. Three indices, i.e. area, perimeter, and circularity of the inserted coils, were investigated on the X-ray images after coil insertion. The coils used were as follows: Target Ultra Helical, MicroPlex Hypersoft, Axium Helix, ED Coil Extrasoft, and DeltaPlush. In the analysis of area and perimeter, there were significant differences in multiple comparisons. There was no significant difference in circularity, although it was generally ranked in order by coil brand. Target Ultra and MicroPlex Hypersoft had higher scores for area and perimeter and lower scores for circularity, in contrast to DeltaPlush, which had lower scores for area and perimeter and a higher score for circularity. Based on these results, the finishing coils were divided into three groups: Target Ultra Helical and MicroPlex Hypersoft; Axium Helix and ED Coil Extrasoft; DeltaPlush. They are better for use in early, midst, and end of finishing, respectively. The characteristics of various finishing coils were evaluated, and the results obtained reflected actual clinical experience and provide useful information to appropriately select finishing coils.

Indexed as

Embolization, TherapeuticEquipment DesignEquipment Failure AnalysisIntracranial AneurysmModels, TheoreticalNylonsNylonscoilembolizationinterventionIntracranial aneurysm

Identifiers

PMID28304201
PMCPMC5433609

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked