Evidence map›Paper›PMID 28303535›Full record

ArticleClinical orthopaedics and related research2017

Hyaluronic Acid-Based Hydrogel Coating Does Not Affect Bone Apposition at the Implant Surface in a Rabbit Model.

W Boot, D Gawlitta, P G J Nikkels, B Pouran, M H P van Rijen, W J A Dhert, H Ch Vogely

Open access · hybridAbstract read
In one paragraph

Article in Clinical orthopaedics and related research, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
4.2field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 35 citations in OpenAlex.

  1. Trial
  2. Use of a Bioresorbable Antibacterial Coating (DACAntibiotics (Basel, Switzerland) · 2026
    Article
  3. Article
  4. Review
  5. Article
  6. Review
  7. Review
  8. Antibacterial hydrogel coating in joint mega-prosthesis: results of a comparative series.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2021
    Article
  9. Review
  10. Review
  11. Review
  12. Article
  13. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

W BootDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands. w.boot@umcutrecht.nl.ORCID http://orcid.org/0000-0001-7150-6007
D GawlittaDepartment of Oral and Maxillofacial Surgery & Special Dental Care, University Medical Center Utrecht, Utrecht, The Netherlands.
P G J NikkelsDepartment of Pathology, University Medical Center Utrecht, Utrecht, The Netherlands.
B PouranDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
M H P van RijenDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
W J A DhertFaculty of Veterinary Medicine, Utrecht University, Utrecht, The Netherlands.
H Ch VogelyDepartment of Orthopaedics, University Medical Center Utrecht, Utrecht, The Netherlands.
University Medical Center Utrecht · NLUtrecht University · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundUncemented orthopaedic implants rely on the bone-implant interface to provide stability, therefore it is essential that a coating does not interfere with the bone-forming processes occurring at the implant interface. In addition, local application of high concentrations of antibiotics for prophylaxis or treatment of infection may be toxic for osteoblasts and could impair bone growth. QUESTIONS/PURPOSES: In this animal study, we investigated the effect of a commercially available hydrogel, either unloaded or loaded with 2% vancomycin. We asked, does unloaded hydrogel or hydrogel with vancomycin (1) interfere with bone apposition and timing of bone deposition near the implant surface; and (2) induce a local or systemic inflammatory reaction as determined by inflammation around the implant and hematologic parameters.

methodsIn 18 New Zealand White rabbits, an uncoated titanium rod (n = 6), a rod coated with unloaded hydrogel (n = 6), or a rod coated with 2% vancomycin-loaded hydrogel (n = 6) was implanted in the intramedullary canal of the left tibia. After 28 days, the bone volume fraction near the implant was measured with microCT analysis, inflammation was semiquantitatively scored on histologic sections, and timing of bone apposition was followed by semiquantitative scoring of fluorochrome incorporation on histologic sections. Two observers, blinded to the treatment, scored the sections and reconciled their scores if there was a disagreement. The hematologic inflammatory reaction was analyzed by measuring total and differential leukocyte counts and erythrocyte sedimentation rates in blood. With group sizes of six animals per group, we had 79% power to detect a difference of 25% in histologic scoring for infection and inflammation.

resultsNo differences were found in the amount of bone apposition near the implant in the No Gel group (48.65% ± 14.95%) compared with the Gel group (59.97% ± 5.02%; mean difference [MD], 11.32%; 95% CI, -3.89% to 26.53%; p = 0.16) or for the Van2 group (56.12% ± 10.06%; MD, 7.46; 95% CI, -7.75 to 22.67; p = 0.40), with the numbers available. In addition, the scores for timing of bone apposition did not differ between the No Gel group (0.50 ± 0.55) compared with the Gel group (0.33 ± 0.52; MD, -0.17; 95% CI, -0.86 to 0.53; p = 0.78) or the Van2 group (0.83 ± 0.41; MD, 0.33; 95% CI, -0.36 to 1.03; p = 0.42). Furthermore, we detected no differences in the histopathology scores for inflammation in the No Gel group (2.33 ± 1.67) compared with the Gel group (3.17 ± 1.59; MD, 0.83; 95% CI, -0.59 to 2.26; p = 0.31) or to the Van2 group (2.5 ± 1.24; MD, 0.17; 95% CI, -1.26 to 1.59; p = 0.95). Moreover, no differences in total leukocyte count, erythrocyte sedimentation rate, and neutrophil, monocyte, eosinophil, basophil, and lymphocyte counts were present between the No Gel or Van2 groups compared with the Gel control group, with the numbers available.

conclusionThe hydrogel coated on titanium implants, unloaded or loaded with 2% vancomycin, had no effect on the volume or timing of bone apposition near the implant, and did not induce an inflammatory reaction in vivo, with the numbers available. CLINICAL RELEVANCE: Antibiotic-loaded hydrogel may prove to be a valuable option to protect orthopaedic implants from bacterial colonization. Future clinical safety studies will need to provide more evidence that this product does not impair bone formation near the implant and prove the safety of this product.

Indexed as

Prostheses and ImplantsAnimalsBone-Implant InterfaceHyaluronic AcidHydrogel, Polyethylene Glycol DimethacrylateModels, AnimalRabbitsTibiaTitaniumVancomycinHyaluronic AcidHydrogel, Polyethylene Glycol DimethacrylateTitaniumVancomycin

Identifiers

PMID28303535
PMCPMC5449332
OpenAlexW2596478859

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.