ReviewJournal of diabetes science and technology2017
Inpatient Continuous Glucose Monitoring and Glycemic Outcomes.
Review in Journal of diabetes science and technology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to 2 registered trials, which are not on this map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Continuous Glucose Monitoring of Hospitalized Patients With Diabetes: A Pilot Study to Establish Evidence
Flash CONtinous Glucose Monitoring in TRansition to Outpatient: Libre for Type 2 Diabetes Mellitus (CONTROL-DM)
Who cites it
21 citing papers in PubMed, 33 citations in OpenAlex.
- Composite Metric of Glycemic Control Q-Score Is Elevated in Pediatric and Adolescent/Young Adult Hematopoietic Stem Cell Transplant Recipients.Diabetes technology & therapeutics · 2023Trial
- Insulin Pump and Continuous Glucose Monitor Initiation in Hospitalized Patients with Type 2 Diabetes Mellitus.Diabetes technology & therapeutics · 2018Trial
- Outcomes of Diabetes Management with Continuous Glucose Monitoring Technology.Archives of internal medicine research · 2026Article
- Evaluation of a subcutaneous continuous glucose monitoring system in critically ill neonatal foals.Journal of veterinary internal medicine · 2026Article
- Association of continuous glucose monitoring with in-hospital adverse outcomes among critically ill patients: a real-world propensity score-matched study.Frontiers in endocrinology · 2026Article
- Reliability of Inpatient CGM: Comparison to Standard of Care.Journal of diabetes science and technology · 2023Article
- Use of Continuous Glucose Monitoring in Non-ICU Hospital Settings for People With Diabetes: A Scoping Review of Emerging Benefits and Issues.Journal of diabetes science and technology · 2023Article
- Consumer Wearables for Patient Monitoring in Otolaryngology: A State of the Art Review.Otolaryngology--head and neck surgery : official journal of American Academy of Otolaryngology-Head and Neck Surgery · 2022Review
- Continuous glucose monitoring in the hospital: an update in the era of COVID-19.Current opinion in endocrinology, diabetes, and obesity · 2022Review
- Impact of electronic health records on predefined safety outcomes in patients admitted to hospital: a scoping review.BMJ open · 2021Article
- Inpatient Hyperglycemia Management and COVID-19.Diabetes therapy : research, treatment and education of diabetes and related disorders · 2021Review
- Reducing Inpatient Hypoglycemia in the General Wards Using Real-time Continuous Glucose Monitoring: The Glucose Telemetry System, a Randomized Clinical Trial.Diabetes care · 2020Article
- Hypoglycemia Incidence and Factors Associated in a Cohort of Patients With Type 2 Diabetes Hospitalized in General Ward Treated With Basal Bolus Insulin Regimen Assessed by Continuous Glucose Monitoring.Journal of diabetes science and technology · 2020Article
- Future technology-enabled care for diabetes and hyperglycemia in the hospital setting.World journal of diabetes · 2019Article
- Glucose Management Technologies for the Critically Ill.Journal of diabetes science and technology · 2019Review
- Advancing the Use of CGM Devices in a Non-ICU Setting.Journal of diabetes science and technology · 2019Review
- Designing the Glucose Telemetry for Hospital Management: From Bedside to the Nursing Station.Current diabetes reports · 2018Review
- Diabetes Technology Update: Use of Insulin Pumps and Continuous Glucose Monitoring in the Hospital.Diabetes care · 2018Review
- The Effect of Continuous Glucose Monitoring in Preventing Inpatient Hypoglycemia in General Wards: The Glucose Telemetry System.Journal of diabetes science and technology · 2018Article
- Continuous Glucose Monitoring in the Cardiac ICU: Current Use and Future Directions.Clinical medicine research · 2017Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Continuous glucose monitoring (CGM) is commonly used in the outpatient setting to improve diabetes management. CGM can provide real-time glucose trends, detecting hyperglycemia and hypoglycemia before the onset of clinical symptoms. In 2011, at the time the Endocrine Society CGM guidelines were published, the society did not recommend inpatient CGM as its efficacy and safety were unknown. While many studies have subsequently evaluated inpatient CGM accuracy and reliability, glycemic outcome studies have not been widely published. In the non-ICU setting, investigational CGM studies have commonly blinded providers and patients to glucose data. Retrospective review of the glucose data reflects increased hypoglycemia detection with CGM. In the ICU setting, data are inconsistent whether CGM can improve glycemic outcomes. Studies have not focused on hospitalized patients with type 1 diabetes mellitus, the population most likely to benefit from inpatient CGM. This article reviews inpatient CGM glycemic outcomes in the non-ICU and ICU setting.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.