Evidence map›Paper›PMID 28289703›Full record

ArticleIEEE robotics and automation letters2017

Autonomous Retroflexion of a Magnetic Flexible Endoscope.

Piotr R Slawinski, Addisu Z Taddese, Kyle B Musto, Keith L Obstein, Pietro Valdastri

Open access · greenAbstract read
In one paragraph

Article in IEEE robotics and automation letters, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.

0numbers the graph read from it
0cells of the map it votes in
13citing papers in PubMed
2.2field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

13 citing papers in PubMed, 49 citations in OpenAlex.

  1. The era of autonomous surgical robotics in thoracic surgery: is it coming?International journal of surgery (London, England) · 2026
    Article
  2. Artificial intelligence: revolutionizing robotic surgery: review.Annals of medicine and surgery (2012) · 2024
    Review
  3. Review
  4. Review
  5. Robotic Autonomy for Magnetic Endoscope Biopsy.IEEE transactions on medical robotics and bionics · 2022
    Article
  6. Magnetic Soft Materials and Robots.Chemical reviews · 2022
    Review
  7. Closed-loop control of soft continuum manipulators under tip follower actuation.The International journal of robotics research · 2021
    Article
  8. Article
  9. Article
  10. Sensitivity Ellipsoids for Force Control of Magnetic Robots with Localization Uncertainty.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2019
    Article
  11. Article
  12. Article
  13. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Piotr R SlawinskiThe Science and Technology of Robotics in Medicine (STORM) Laboratory, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Addisu Z TaddeseThe Science and Technology of Robotics in Medicine (STORM) Laboratory, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Kyle B MustoThe Science and Technology of Robotics in Medicine (STORM) Laboratory, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Keith L ObsteinThe Division of Gastroenterology, Hepatology, and Nutrition, Vanderbilt University Medical Center, Nashville, TN, USA; The Science and Technology of Robotics in Medicine (STORM) Laboratory, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Pietro ValdastriThe Institute of Robotics, Autonomous Systems and Sensing, School of Electronic and Electrical Engineering, University of Leeds, Leeds, UK; The Science and Technology of Robotics in Medicine (STORM) Laboratory, Department of Mechanical Engineering, Vanderbilt University, Nashville, TN, USA.
Vanderbilt University · USVanderbilt University Medical Center · US

Funding

A magnetic capsule endoscope for colonoscopy in patients with inflammatory bowel diseaseR01EB018992 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI OBSTEIN, KEITH L · 2014 to 2024
$2.8M
NIBIB NIH HHS R01 EB018992
6 · The paper itself

Abstract

Retroflexion during colonoscopy is typically only practiced in the wider proximal and distal ends of the large intestine owing to the stiff nature of the colonoscope. This inability to examine the proximal side of the majority of colon folds contributes to today's suboptimal colorectal cancer detection rates. We have developed an algorithm for autonomous retroflexion of a flexible endoscope that is actuated magnetically from the tip. The magnetic wrench applied on the tip of the endoscope is optimized in real-time with data from pose detection to compute motions of the actuating magnet. This is the first example of a completely autonomous maneuver by a magnetic endoscope for exploration of the gastrointestinal tract. The proposed approach was validated in plastic tubes of various diameters with a success rate of 98.8% for separation distances up to 50 mm. Additionally, a set of trials was conducted in an excised porcine colon observing a success rate of 100% with a mean time of 19.7 s. In terms of clinical safety, the maximum stress that is applied on the colon wall with our methodology is an order of magnitude below what would damage tissue.

Indexed as

Flexible robotsMedical Robots and SystemsMotion Control

Identifiers

PMID28289703
PMCPMC5345942
OpenAlexW2588930121

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.