Evidence map›Paper›PMID 28288587›Full record

ArticleBMC anesthesiology2017

The value of arterial pressure waveform cardiac output measurements in the radial and femoral artery in major cardiac surgery patients.

A van Drumpt, J van Bommel, S Hoeks, F Grüne, T Wolvetang, J Bekkers, M Ter Horst

Open access · goldAbstract readValidation Study
In one paragraph

Article in BMC anesthesiology, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 1 synthesis or guideline pooled it, 18 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Observational
  5. Review
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

A van DrumptDepartment of Anesthesiology, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands. annevandrumpt@hotmail.com.ORCID 0000-0003-0478-8889
J van BommelDepartment of Intensive Care Adults, Erasmus Medical Center, Rotterdam, The Netherlands.
S HoeksDepartment of Anesthesiology, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
F GrüneDepartment of Anesthesiology, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
T WolvetangDepartment of Anesthesiology, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
J BekkersDepartment of Cardiothoracic Surgery, Erasmus Medical Center, Rotterdam, The Netherlands.
M Ter HorstDepartment of Anesthesiology, Erasmus Medical Center, PO Box 2040, 3000 CA, Rotterdam, The Netherlands.
Erasmus MC · NL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundA relatively new uncalibrated arterial pressure waveform cardiac output (CO) measurement technique is the Pulsioflex-ProAQT® system. Aim of this study was to validate this system in cardiac surgery patients with a specific focus on the evaluation of a difference in the radial versus the femoral arterial access, the value of the auto-calibration modus and the ability to show fluid-induced changes.

methodsIn twenty-five patients scheduled for ascending aorta, aortic arch replacement, or both we measured CO simultaneously by transpulmonary thermodilution (COtd) and by using the ProAQT® system connected to the radial (COpR), as well as the femoral artery catheter (COpF). Hemodynamic data were assessed at predefined time points; from incision until 16 h after ICU admission.

resultsIn total 175 (radial) and 179 (femoral) pairs of CO measurement were collected. The accuracy of COpR/COpF was evaluated showing a mean bias of -0.31 L/min (±2.9 L/min) and -0.57 L/min (± 2.8 L/min) with percentage errors of 49 and 46% respectively. Trending ability of the ProAQT® device was evaluated; the four quadrant concordance rates in the radial and femoral artery were 74 and 75% and improved to 77 and 85% after auto-calibration. The mean angular biases in the radial and femoral artery were 6.4° and 6.0° and improved to 5° and 3.3° after auto-calibration. The polar concordance rates in the radial and femoral artery were 65 and 70% and improved to 76 and 84% after auto-calibration. Considering the fluid-induced changes in stroke volume(SV), the coefficient of correlation between the changes in SVtd and SVp was 0.57 (p < 0.01) in the radial artery and 0.60 (p < 0.01) in the femoral artery.

conclusionsThe ProAQT® system can be of additional value if the clinician wants to determine fluid responsiveness in cardiac surgery patients. However, the ProAQT® system provided inaccurate CO measurements compared to transpulmonary thermodilution. The trending ability was poor for COpR but moderate for COpF. Auto-calibration of the system did not improve accuracy of CO measurements nor did it improve the prediction of fluid responsiveness. However, the trending ability was improved by auto-calibration, possibly by correcting a drift over a longer time period.

Indexed as

Cardiac Surgical ProceduresAgedBlood PressureCardiac OutputCathetersFemaleFemoral ArteryHumansMaleMonitoring, IntraoperativeProspective StudiesRadial ArteryThermodilutionAgreementCardiac outputFluid responsivenessPulse contour analysisTranspulmonary thermodilutionTrending ability

Identifiers

PMID28288587
PMCPMC5348755
OpenAlexW2596708674

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.