Validation of a CT-guided intervention robot for biopsy and radiofrequency ablation: experimental study with an abdominal phantom.
Article in Diagnostic and interventional radiology (Ankara, Turkey). The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed, 1 synthesis or guideline pooled it.
- Democratization in abdominal ablation therapies: The impact of percutaneous robotic assistance on accuracy-A systematic review.Journal of robotic surgery · 2025Pooled it
- A review of image guidance and localization methods for liver puncture robots.Journal of robotic surgery · 2025Review
- Article
- Robotic Assistance in Percutaneous Liver Ablation Therapies: A Systematic Review and Meta-Analysis.Annals of surgery open : perspectives of surgical history, education, and clinical approaches · 2024Article
- CRANE: A Redundant, Multi-Degree-of-Freedom Computed Tomography Robot for Heightened Needle Dexterity within a Medical Imaging Bore.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2024Article
- Towards Autonomous Robotic Biopsy-Design, Modeling and Control of a Robot for Needle Insertion of a Commercial Full Core Biopsy Instrument.Frontiers in robotics and AI · 2022Article
- Clinical evaluation of a robotic system for precise CT-guided percutaneous procedures.Abdominal radiology (New York) · 2021Article
- Robot-Assisted Image-Guided Interventions.Frontiers in robotics and AI · 2021Review
- Accuracy study of a binocular-stereo-vision-based navigation robot for minimally invasive interventional procedures.World journal of clinical cases · 2020Article
- Smartphone Augmented Reality CT-Based Platform for Needle Insertion Guidance: A Phantom Study.Cardiovascular and interventional radiology · 2020Article
- Optimization Model for the Distribution of Fiducial Markers in Liver Intervention.Journal of medical systems · 2020Article
- Robotic needle insertion during computed tomography fluoroscopy-guided biopsy: prospective first-in-human feasibility trial.European radiology · 2020Observational
- The relative risk to the femoral nerve as a function of patient positioning: potential implications for trigger point dry needling of the iliacus muscle.The Journal of manual & manipulative therapy · 2019Article
- Accuracy of semi-automated versus manual localisation of liver tumours in CT-guided ablation procedures.European radiology · 2018Article
- A radiopaque 3D printed, anthropomorphic phantom for simulation of CT-guided procedures.European radiology · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposeWe aimed to evaluate the accuracy of a needle-placement robot for biopsy and radiofrequency ablation on an abdominal phantom.
methodsA master-slave robotic system has been developed that includes a needle-path planning system and a needle-inserting robot arm with computed tomography (CT) and CT fluoroscopy guidance. For evaluation of its accuracy in needle placement, a commercially available abdominal phantom (Model 057A; CIRS Inc.) was used. The liver part of the phantom contains multiple spherical simulated tumors of three different size spheres. Various needle insertion trials were performed in the transverse plane and caudocranial plane two nodule sizes (10 mm and 20 mm in diameter) to test the reliability of this robot. To assess accuracy, a CT scan was performed after each trial with the needle in situ.
resultsThe overall error was 2 mm (0-2.6 mm), which was calculated as the distance from the planned trajectory before insertion to the actual needle trajectory after insertion. The standard deviations of the insertions on two nodules (10 mm and 20 mm in diameter) were 0.5 mm and 0.2 mm, respectively.
conclusionThe CT-compatible needle placement robot for biopsy and radiofrequency ablation shows relatively acceptable accuracy and could be used for radiofrequency ablation of nodules ≥10 mm under CT fluoroscopy guidance.