Closed Loop Control of a Tethered Magnetic Capsule Endoscope.

Addisu Z Taddese, Piotr R Slawinski, Keith L Obstein, Pietro Valdastri

Abstract read
In one paragraph

Article in Robotics science and systems : online proceedings, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed.

  1. Article
  2. A Novel Biopsy Capsule Robot Based on High-Speed Cutting Tissue.Cyborg and bionic systems (Washington, D.C.) · 2022
    Article
  3. Article
  4. Sensitivity Ellipsoids for Force Control of Magnetic Robots with Localization Uncertainty.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2019
    Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Autonomous Retroflexion of a Magnetic Flexible Endoscope.IEEE robotics and automation letters · 2017
    Article
  10. Nonholonomic Closed-loop Velocity Control of a Soft-tethered Magnetic Capsule Endoscope.Proceedings of the ... IEEE/RSJ International Conference on Intelligent Robots and Systems. IEEE/RSJ International Conference on Intelligent Robots and Systems · 2016
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Addisu Z TaddeseMechanical Engineering Department, Vanderbilt University, Nashville, TN, USA.
Piotr R SlawinskiMechanical Engineering Department, Vanderbilt University, Nashville, TN, USA.
Keith L ObsteinDivision of Gastroenterology, Hepatology, and Nutrition, Vanderbilt University Medical Center, Nashville, TN, USA.
Pietro ValdastriMechanical Engineering Department, Vanderbilt University, Nashville, TN, USA.

Funding

A magnetic capsule endoscope for colonoscopy in patients with inflammatory bowel diseaseR01EB018992 · NIBIB · VANDERBILT UNIVERSITY MEDICAL CENTER · PI OBSTEIN, KEITH L · 2014 to 2024
$2.8M
NIBIB NIH HHS R01 EB018992
6 · The paper itself

Abstract

Magnetic field gradients have repeatedly been shown to be the most feasible mechanism for gastrointestinal capsule endoscope actuation. An inverse quartic magnetic force variation with distance results in large force gradients induced by small movements of a driving magnet; this necessitates robotic actuation of magnets to implement stable control of the device. A typical system consists of a serial robot with a permanent magnet at its end effector that actuates a capsule with an embedded permanent magnet. We present a tethered capsule system where a capsule with an embedded magnet is closed loop controlled in 2 degree-of-freedom in position and 2 degree-of-freedom in orientation. Capitalizing on the magnetic field of the external driving permanent magnet, the capsule is localized in 6-D allowing for both position and orientation feedback to be used in a control scheme. We developed a relationship between the serial robot's joint parameters and the magnetic force and torque that is exerted onto the capsule. Our methodology was validated both in a dynamic simulation environment where a custom plug-in for magnetic interaction was written, as well as on an experimental platform. The tethered capsule was demonstrated to follow desired trajectories in both position and orientation with accuracy that is acceptable for colonoscopy.

Identifiers

PMID28286886
PMCPMC5345944

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.