Evidence map›Paper›PMID 28284488›Full record

ArticleCortex; a journal devoted to the study of the nervous system and behavior2017

Agnosic vision is like peripheral vision, which is limited by crowding.

Francesca Strappini, Denis G Pelli, Enrico Di Pace, Marialuisa Martelli

Open access · hybridAbstract read
In one paragraph

Article in Cortex; a journal devoted to the study of the nervous system and behavior, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
1.2field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 20 citations in OpenAlex.

  1. Article
  2. Human V4 size predicts crowding distance.Nature communications · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 3 countries.

Francesca StrappiniDepartment of Psychology, University of Rome La Sapienza, Rome, Italy; Neuropsychology Research Centre, IRCCS Foundation Hospital Santa Lucia, Rome, Italy; Neurobiology Department, Weizmann Institute of Science, Rehovot, Israel.
Denis G PelliDepartment of Psychology and Center for Neural Science, New York University, New York, NY, USA.
Enrico Di PaceDepartment of Psychology, University of Rome La Sapienza, Rome, Italy.
Marialuisa MartelliDepartment of Psychology, University of Rome La Sapienza, Rome, Italy; Neuropsychology Research Centre, IRCCS Foundation Hospital Santa Lucia, Rome, Italy. Electronic address: marialuisa.martelli@uniroma1.it.
Fondazione Santa Lucia · ITNew York University · USSapienza University of Rome · IT

Funding

Vision Core Grant- Design and Fabrication ModuleP30EY013079 · NEI · NEW YORK UNIVERSITY · PI MOVSHON, J ANTHONY · 2000 to 2025
$14.2M
TRANSMISSION OF INFORMATION IN VISUAL SYSTEMR01EY004432 · NEI · SYRACUSE UNIVERSITY AT SYRACUSE · PI PELLI, DENIS G · 1985 to 2010
$2.1M
NEI NIH HHS P30 EY013079NEI NIH HHS R01 EY004432
6 · The paper itself

Abstract

Visual agnosia is a neuropsychological impairment of visual object recognition despite near-normal acuity and visual fields. A century of research has provided only a rudimentary account of the functional damage underlying this deficit. We find that the object-recognition ability of agnosic patients viewing an object directly is like that of normally-sighted observers viewing it indirectly, with peripheral vision. Thus, agnosic vision is like peripheral vision. We obtained 14 visual-object-recognition tests that are commonly used for diagnosis of visual agnosia. Our "standard" normal observer took these tests at various eccentricities in his periphery. Analyzing the published data of 32 apperceptive agnosia patients and a group of 14 posterior cortical atrophy (PCA) patients on these tests, we find that each patient's pattern of object recognition deficits is well characterized by one number, the equivalent eccentricity at which our standard observer's peripheral vision is like the central vision of the agnosic patient. In other words, each agnosic patient's equivalent eccentricity is conserved across tests. Across patients, equivalent eccentricity ranges from 4 to 40 deg, which rates severity of the visual deficit. In normal peripheral vision, the required size to perceive a simple image (e.g., an isolated letter) is limited by acuity, and that for a complex image (e.g., a face or a word) is limited by crowding. In crowding, adjacent simple objects appear unrecognizably jumbled unless their spacing exceeds the crowding distance, which grows linearly with eccentricity. Besides conservation of equivalent eccentricity across object-recognition tests, we also find conservation, from eccentricity to agnosia, of the relative susceptibility of recognition of ten visual tests. These findings show that agnosic vision is like eccentric vision. Whence crowding? Peripheral vision, strabismic amblyopia, and possibly apperceptive agnosia are all limited by crowding, making it urgent to know what drives crowding. Acuity does not (Song et al., 2014), but neural density might: neurons per deg

Indexed as

AdolescentAdultAgedAgnosiaChildFemaleHumansMaleMiddle AgedPattern Recognition, VisualRecognition, PsychologyVision, OcularVision TestsVisual PerceptionYoung AdultApperceptive agnosiaCrowdingIntegration deficitIntegrative agnosiaNeural densityObject recognitionVisual agnosia

Identifiers

PMID28284488
PMCPMC8493918
OpenAlexW2584500391

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.