ArticleSurgical endoscopy2017
ICG fluorescence imaging for quantitative evaluation of colonic perfusion in laparoscopic colorectal surgery.
Article in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04904081 (The Use of Indocyanine Green Angiography in Pediatric Colorectal Surgery), which is not on this map. Cited by 126 papers, 13 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Use of Indocyanine Green Angiography in Pediatric Colorectal Surgery: A Feasibility Randomized Controlled Trial
Who cites it
126 citing papers in PubMed, 13 syntheses or guidelines pooled it, 209 citations in OpenAlex.
- The use of indocyanine green for colorectal anastomoses: a systematic review and meta-analysis.Annals of the Royal College of Surgeons of England · 2025Pooled it
- Indocyanine green and height of anastomosis in colorectal surgery- a network meta-analysis.Langenbeck's archives of surgery · 2025Pooled it
- Quantification of indocyanine green fluorescence angiography in colorectal surgery: a systematic review of the literature.Surgical endoscopy · 2025Pooled it
- Evaluation of anastomotic blood supply during digestive tract reconstruction with the use of the oxygen saturation index: A pooling up analysis.International journal of colorectal disease · 2025Pooled it
- Application of fluorescence-guided surgery in the acute care setting: a systematic literature review.Langenbeck's archives of surgery · 2023Pooled it
- Intraoperative bowel perfusion assessment methods and their effects on anastomotic leak rates: meta-analysis.The British journal of surgery · 2023Pooled it
- Effect of indocyanine green fluorescence angiography on preventing anastomotic leakage after colorectal surgery: a meta-analysis.Surgery today · 2021Pooled it
- Defining indocyanine green fluorescence to assess anastomotic perfusion during gastrointestinal surgery: systematic review.BJS open · 2021Pooled it
- The efficacy of intraoperative ICG fluorescence angiography on anastomotic leak after resection for colorectal cancer: a meta-analysis.International journal of colorectal disease · 2021Pooled it
- Assessment of intraoperative use of indocyanine green fluorescence imaging on the incidence of anastomotic leakage after rectal cancer surgery: a PRISMA-compliant systematic review and meta-analysis.Techniques in coloproctology · 2021Pooled it
- Does intraoperative indocyanine green fluorescence angiography decrease the incidence of anastomotic leakage in colorectal surgery? A systematic review and meta-analysis.International journal of colorectal disease · 2021Pooled it
- Optimizing quantitative fluorescence angiography for visceral perfusion assessment.Surgical endoscopy · 2020Pooled it
- Intraoperative testing of colorectal anastomosis and the incidence of anastomotic leak: A meta-analysis.Medicine · 2020Pooled it
- Quantitative evaluation of colon perfusion after high versus low ligation in rectal surgery by indocyanine green: a pilot study.Surgical endoscopy · 2022Trial
- Computer-assisted quantification and visualization of bowel perfusion using fluorescence-based enhanced reality in left-sided colonic resections.Surgical endoscopy · 2021Trial
- Safety and effectiveness of high ligation of the inferior mesenteric artery for cancer of the descending colon under indocyanine green fluorescence imaging: a pilot study.Surgical endoscopy · 2021Trial
- [Evidence of indocyanine green fluorescence in robotically assisted colorectal surgery : What is the status?]Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen · 2021Trial
- Comparison of hyperspectral imaging and fluorescence angiography for the determination of the transection margin in colorectal resections-a comparative study.International journal of colorectal disease · 2021Trial
- Remote computer-assisted analysis of ICG fluorescence signal for evaluation of small intestinal anastomotic perfusion: a blinded, randomized, experimental trial.Surgical endoscopy · 2020Trial
- The effects of intraoperative ICG fluorescence angiography in laparoscopic low anterior resection: a propensity score-matched study.International journal of clinical oncology · 2019Trial
66 more citing papers are in PubMed but not listed here.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundFluorescence technology with indocyanine green (ICG) provides a real-time assessment of intestinal perfusion. However, a subjective evaluation of fluorescence intensity based on the surgeon's visual judgement is a major limitation. This study evaluated the quantitative assessment of ICG fluorescence imaging in determining the transection line of the proximal colon during laparoscopic colorectal surgery.
methodsThis is a retrospective analysis of a prospectively maintained database of 112 patients who underwent laparoscopic surgery for left-sided colorectal cancers. After distal transection of the bowel, the specimen was extracted extracorporeally and then the proximal colon was divided within the well-perfused area based on the ICG fluorescence imaging. We evaluated whether quantitative assessment of intestinal perfusion by measuring ICG intensity could predict postoperative outcomes: F
resultsAnastomotic leakage (AL) occurred in 5 cases (4.5%). Based on the fluorescence imaging, the surgical team opted for further proximal change of the transection line up to an "adequate" fluorescent portion in 18 cases (16.1%). Among the 18 patients, AL occurred in 4 patients (4/18: 22.2%), whereas it occurred in only 1 case (1/94: 1.0%) in the good perfusion patients who did not need proximal change of the transection line. The F
conclusionsICG fluorescence imaging is useful for assessing anastomotic perfusion in colorectal surgery, which can result in more precise operative decisions tailored for an individual patient.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.