Evidence map›Paper›PMID 28281112›Full record

Trial reportSurgical endoscopy2017

Performance of Kymerax© precision-drive articulating surgical system compared to conventional laparoscopic instruments in a pelvitrainer model.

Marco Alain Sieber, Bernhard Fellmann-Fischer, Michael Mueller

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Trial
  2. Trial
  3. Trial
  4. Trial
  5. Trial
  6. Article
  7. Article
  8. Article
  9. Review
  10. Article
  11. Article
  12. Review
  13. Pneumatically driven surgical forceps displaying a magnified grasping torque.The international journal of medical robotics + computer assisted surgery : MRCAS · 2020
    Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Marco Alain SieberUniversity of Bern, Spital Interlaken, Unterseen, Switzerland. sieber.marco@gmx.ch.
Bernhard Fellmann-FischerDepartment of Gynecology, Inselspital Bern, Bern, Switzerland.
Michael MuellerDepartment of Gynecology, Inselspital Bern, Bern, Switzerland.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe Kymerax© Precision-Drive Articulating Surgical System by Terumo© is a handheld laparoscopic robot which permits motion in two additional degrees of freedom (deflection and rotation in the instrument tip). In a pelvitrainer model, we compared the performance of participants with different laparoscopic experiences and compared Kymerax© to conventional laparoscopic instruments.

methods20 expert surgeons, performing more than 50 laparoscopic procedures per year, and 25 medical students without any experience in surgery at all were selected. Each participant was randomized into two groups: Group TK performed the tasks using the traditional laparoscopic Instruments (TLI) first and Kymerax© thereafter, group KT vice versa. Six standardized tasks were used: Two instructional exercises and four tasks where time, number of mistakes, and overall precision were measured. Finally, a questionnaire had to be answered.

resultsAll four tasks were performed significantly more slowly with the Kymerax© device. Improved needle control in stitches towards the surgeon, significantly less deviation while cutting along different lines as well as a significantly reduced fraying of the cutting edge were found when participants were using Kymerax©. By questionnaire more than 90% of the participants indicated clear advantages using Kymerax©. However, participants needed more training time and had an earlier loss of concentration with Kymerax©. Further complaints about Kymerax© were its limitations in rotation and deflection, the impaired view as well as the non-ergonomic instrument handle. Rotation force, instrument weight, digital instrument-tip control, and needle fixation were rated as accurate.

conclusionsThis study shows that more time is needed to solve tasks with Kymerax© compared to conventional laparoscopic instruments. Kymerax© is superior to conventional laparoscopy for suturing at difficult angles and cutting along complex structures. Kymerax© can potentially bring benefits for certain laparoscopic tasks, but as seen in this study, further developments are necessary. Terumo© meanwhile closed down its Kymerax

Indexed as

Simulation TrainingHumansLaparoscopyLearning CurveRobotic Surgical ProceduresDegrees of freedomGynecologyHandheld robotKymeraxLaparoscopyPelvitrainer

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.