Evidence map›Paper›PMID 28273794›Full record

ArticleSensors (Basel, Switzerland)2017

Development of a Double-Gauss Lens Based Setup for Optoacoustic Applications.

Hojong Choi, Jae-Myung Ryu, Jung-Yeol Yeom

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 24 citations in OpenAlex.

  1. Novel dual-resistor-diode limiter circuit structures for high-voltage reliable ultrasound receiver systems.Technology and health care : official journal of the European Society for Engineering and Medicine · 2022
    Article
  2. Fisheye lens design for solar-powered mobile ultrasound devices.Technology and health care : official journal of the European Society for Engineering and Medicine · 2022
    Article
  3. Development of a low-cost six-axis alignment instrument for flexible 2D and 3D ultrasonic probes.Technology and health care : official journal of the European Society for Engineering and Medicine · 2021
    Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Chromatic aberration free reflective mirror-based optical system design for multispectral photoacoustic instruments.Technology and health care : official journal of the European Society for Engineering and Medicine · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 1 country.

Hojong ChoiDepartment of Medical IT Convergence Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea. hojongch@kumoh.ac.kr.
Jae-Myung RyuDepartment of Optical System Engineering, Kumoh National Institute of Technology, Gumi 39253, Korea. jmryu@kumoh.ac.kr.
Jung-Yeol YeomSchool of Biomedical Engineering, Korea University, Seoul 02841, Korea. jungyeol@korea.ac.kr.
Kumoh National Institute of Technology · KRKorea University · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In optoacoustic (photoacoustic) systems, different echo signal intensities such as amplitudes, center frequencies, and bandwidths need to be compensated by utilizing variable gain or time-gain compensation amplifiers. However, such electronic components can increase system complexities and signal noise levels. In this paper, we introduce a double-Gauss lens to generate a large field of view with uniform light intensity due to the low chromatic aberrations of the lens, thus obtaining uniform echo signal intensities across the field of view of the optoacoustic system. In order to validate the uniformity of the echo signal intensities in the system, an in-house transducer was placed at various positions above a tissue sample and echo signals were measured and compared with each other. The custom designed double-Gauss lens demonstrated negligible light intensity variation (±1.5%) across the illumination field of view (~2 cm diameter). When the transducer was used to measure echo signal from an eye of a bigeye tuna within a range of ±1 cm, the peak-to-peak amplitude, center frequency, and their -6 dB bandwidth variations were less than 2 mV, 1 MHz, and 6%, respectively. The custom designed double-Gauss lens can provide uniform light beam across a wide area while generating insignificant echo signal variations, and thus can lower the burden of the receiving electronics or signal processing in the optoacoustic system.

Indexed as

double-Gauss lensoptoacoustic applicationstransducer

Identifiers

PMID28273794
PMCPMC5375782
OpenAlexW2591799415

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.