Evidence map›Paper›PMID 28269417›Full record

ArticleAnnual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference2016

Robot-assisted retinal vein cannulation with force-based puncture detection: Micron vs. the steady-hand eye robot.

Berk Gonenc, Nhat Tran, Peter Gehlbach, Russell H Taylor, Iulian Iordachita

Open access · greenAbstract readComparative Study
In one paragraph

Article in Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.7field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 22 citations in OpenAlex.

  1. Article
  2. Article
  3. A Feasible Workflow for Retinal Vein Cannulation in Ex Vivo Porcine Eyes with Robotic Assistance.Annual International Conference of the IEEE Engineering in Medicine and Biology Society. IEEE Engineering in Medicine and Biology Society. Annual International Conference · 2024
    Article
  4. Review
  5. Article
  6. Robotic Assistance for Intraocular Microsurgery: Challenges and Perspectives.Proceedings of the IEEE. Institute of Electrical and Electronics Engineers · 2022
    Article
  7. Article
  8. Toward the Art of Robotic-assisted Vitreoretinal Surgery.Journal of ophthalmic & vision research
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Berk Gonenc
Nhat Tran
Peter Gehlbach
Russell H Taylor
Iulian Iordachita
Johns Hopkins University · US

Funding

An Active Handheld MicromanipulatorR01EB000526 · NIBIB · CARNEGIE-MELLON UNIVERSITY · PI RIVIERE, CAMERON N · 2003 to 2017
$2.6M
NIBIB NIH HHS R01 EB000526
6 · The paper itself

Abstract

Retinal vein cannulation is a demanding procedure where therapeutic agents are injected into occluded retina veins. The feasibility of this treatment is limited due to challenges in identifying the moment of venous puncture, achieving cannulation and maintaining it throughout the drug delivery period. In this study, we integrate a force-sensing microneedle with two distinct robotic systems: the handheld micromanipulator Micron, and the cooperatively controlled Steady-Hand Eye Robot (SHER). The sensed tool-to-tissue interaction forces are used to detect venous puncture and extend the robots' standard control schemes with a new position holding mode (PHM) that assists the operator hold the needle position fixed and maintain cannulation for a longer time with less trauma on the vasculature. We evaluate the resulting systems comparatively in a dry phantom, stretched vinyl membranes. Results have shown that modulating the admittance control gain of SHER alone is not a very effective solution for preventing the undesired tool motion after puncture. However, after using puncture detection and PHM the deviation from the puncture point is significantly reduced, by 65% with Micron, and by 95% with SHER representing a potential advantage over freehand for both.

Indexed as

CatheterizationPuncturesBiomechanical PhenomenaEquipment DesignEyeHumansMicromanipulationNeedlesPhantoms, ImagingRetinal VeinRetinal Vein OcclusionRobotics

Identifiers

PMID28269417
PMCPMC5793869
OpenAlexW2538346852

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.