ArticleJournal of clinical densitometry : the official journal of the International Society for Clinical Densitometry
Cross-Calibrated Dual-Energy X-Ray Absorptiometry Scanners Demonstrate Systematic Bias in Pediatric and Young Adult Females.
Article in Journal of clinical densitometry : the official journal of the International Society for Clinical Densitometry. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 8 citations in OpenAlex.
- Peak bone mass development in U.S. females with varied physical activity patterns: a longitudinal view using three maturational clocks.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2026Article
- Biological Benchmarks for Adult Bone Mass Proportions in Young Females: A Prospective Longitudinal Analysis.American journal of human biology : the official journal of the Human Biology Council · 2025Article
- Transition of young adults with metabolic bone diseases to adult care.Frontiers in endocrinology · 2023Review
- Dual-energy x-ray absorptiometry scanner mismatch in follow-up bone mineral density testing.Osteoporosis international : a journal established as result of cooperation between the European Foundation for Osteoporosis and the National Osteoporosis Foundation of the USA · 2022Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 3 institutions in 1 country.
Funding
Abstract
Consistency of dual-energy X-ray absorptiometry (DXA) scan results is critical for data integrity. For pediatric subjects, the extent to which cross-calibration of DXA scanners alleviates model-to-model scanner differences is unclear. In the current study, DXA bone outcomes were compared for same-day measurements performed using different scanners, cross-calibrated to alleviate discrepancies (Hologic; Discovery A [DISCO] and QDR 4500W [QDR]). Interscanner differences were evaluated in approximately 130 females aged 8-24 yr. Scans were performed in a single session on both QDR and DISCO scanners to compare projected area, bone mineral content, and areal bone mineral density (BMD) outputs for the whole body (total, subhead, head, arm, and leg), forearm (1/3 and ultradistal radius), lumbar spine (vertebra L3 and L1-L4), and proximal femur (femoral neck). Paired t tests evaluated interscanner differences; concordance correlation coefficients (CCCs) evaluated interscanner correlations. Root mean square error coefficients of variation were compared to same-day duplicate DISCO scan root mean square error coefficients of variation for approximately 30 adult females. Deming regression equations were generated for conversion of QDR to DISCO results and vice versa. Interscanner correlations were very high (95% confidence interval for CCC > 0.90), for all outcomes except for femoral neck area and subhead area (95% confidence interval for CCC = 0.83-0.94, 0.57-073). However, QDR values were systematically lower than Discovery values (p < 0.05), except for head area, head bone mineral content, head BMD, ultradistal BMD (QDR > Discovery, p ≤ 0.05) and L1-L4 area, L3 area, and femoral neck BMD (no differences). Most Bland-Altman and Deming regression plots indicated good interscanner agreement, with little systematic variation based on bone or body size. In pediatric and young adult females, subtle but systematic differences were noted between scans obtained on DISCO and QDR scanners, despite cross-calibration, such that most outcomes are systematically higher for DISCO than for QDR. The use of conversion equations is warranted.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.