ArticlePloS one2017
Multiband multi-echo imaging of simultaneous oxygenation and flow timeseries for resting state connectivity.
Article in PloS one, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 21 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
21 citing papers in PubMed, 32 citations in OpenAlex.
- A large-scale heterogeneous 3D magnetic resonance brain imaging dataset for self-supervised learning.Scientific data · 2026Article
- Optimization of deep learning-based denoising for arterial spin labeling: Effects of averaging and training strategies.Magnetic resonance in medicine · 2025Article
- Robust-tedana: An automated denoising pipeline for multi-echo fMRI data.bioRxiv : the preprint server for biology · 2025Article
- Hypoxia's Impact on Hippocampal Functional Connectivity: Insights from Resting-State fMRI Studies.Brain sciences · 2025Review
- Resting state BOLD-perfusion coupling patterns using multiband multi-echo pseudo-continuous arterial spin label imaging.Scientific reports · 2025Article
- Changes in cerebrovascular reactivity within functional networks in older adults with long-COVID.Frontiers in neurology · 2025Article
- Comparing the effect of multi-gradient echo and multi-band fMRI during a semantic task.Imaging neuroscience (Cambridge, Mass.) · 2025Article
- Molecular-enriched functional connectivity in the human brain using multiband multi-echo simultaneous ASL/BOLD fMRI.Scientific reports · 2023Article
- Improved Resting-State Functional MRI Using Multi-Echo Echo-Planar Imaging on a Compact 3T MRI Scanner with High-Performance Gradients.Sensors (Basel, Switzerland) · 2023Article
- Denoising physiological data collected during multi-band, multi-echo EPI sequences.Aperture neuro · 2023Article
- Contribution of the multi-echo approach in accelerated functional magnetic resonance imaging multiband acquisition.Human brain mapping · 2022Article
- Using multiband multi-echo imaging to improve the robustness and repeatability of co-activation pattern analysis for dynamic functional connectivity.NeuroImage · 2021Article
- Improved resting state functional connectivity sensitivity and reproducibility using a multiband multi-echo acquisition.NeuroImage · 2021Article
- Improving the Breath-Holding CVR Measurement Using the Multiband Multi-Echo EPI Sequence.Frontiers in physiology · 2021Article
- Does higher sampling rate (multiband + SENSE) improve group statistics - An example from social neuroscience block design at 3T.NeuroImage · 2020Article
- Improving the Assessment of Breath-Holding Induced Cerebral Vascular Reactivity Using a Multiband Multi-echo ASL/BOLD Sequence.Scientific reports · 2019Article
- fMRIPrep: a robust preprocessing pipeline for functional MRI.Nature methods · 2019Article
- The Integration of Functional Brain Activity from Adolescence to Adulthood.The Journal of neuroscience : the official journal of the Society for Neuroscience · 2018Article
- Reduced Dynamic Coupling Between Spontaneous BOLD-CBF Fluctuations in Older Adults: A Dual-Echo pCASL Study.Frontiers in aging neuroscience · 2018Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A novel sequence has been introduced that combines multiband imaging with a multi-echo acquisition for simultaneous high spatial resolution pseudo-continuous arterial spin labeling (ASL) and blood-oxygenation-level dependent (BOLD) echo-planar imaging (MBME ASL/BOLD). Resting-state connectivity in healthy adult subjects was assessed using this sequence. Four echoes were acquired with a multiband acceleration of four, in order to increase spatial resolution, shorten repetition time, and reduce slice-timing effects on the ASL signal. In addition, by acquiring four echoes, advanced multi-echo independent component analysis (ME-ICA) denoising could be employed to increase the signal-to-noise ratio (SNR) and BOLD sensitivity. Seed-based and dual-regression approaches were utilized to analyze functional connectivity. Cerebral blood flow (CBF) and BOLD coupling was also evaluated by correlating the perfusion-weighted timeseries with the BOLD timeseries. These metrics were compared between single echo (E2), multi-echo combined (MEC), multi-echo combined and denoised (MECDN), and perfusion-weighted (PW) timeseries. Temporal SNR increased for the MECDN data compared to the MEC and E2 data. Connectivity also increased, in terms of correlation strength and network size, for the MECDN compared to the MEC and E2 datasets. CBF and BOLD coupling was increased in major resting-state networks, and that correlation was strongest for the MECDN datasets. These results indicate our novel MBME ASL/BOLD sequence, which collects simultaneous high-resolution ASL/BOLD data, could be a powerful tool for detecting functional connectivity and dynamic neurovascular coupling during the resting state. The collection of more than two echoes facilitates the use of ME-ICA denoising to greatly improve the quality of resting state functional connectivity MRI.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.