Evidence map›Paper›PMID 28247297›Full record

ArticleJournal of the American Society for Mass Spectrometry2017

Analysis of Monoclonal Antibodies in Human Serum as a Model for Clinical Monoclonal Gammopathy by Use of 21 Tesla FT-ICR Top-Down and Middle-Down MS/MS.

Lidong He, Lissa C Anderson, David R Barnidge, David L Murray, Christopher L Hendrickson, Alan G Marshall

Erratum issuedAbstract read
PubMed Publisher
In one paragraph

Article in Journal of the American Society for Mass Spectrometry, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 28 papers.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed.

  1. Top-Down and Middle-Down Mass Spectrometry of Antibodies.Molecular & cellular proteomics : MCP · 2025
    Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
  7. Article
  8. Article
  9. Glycoproteomics Technologies in Glycobiotechnology.Advances in biochemical engineering/biotechnology · 2021
    Article
  10. Selectivity over coverage inChemical science · 2020
    Article
  11. Article
  12. Article
  13. Article
  14. Review
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Review
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Lidong HeDepartment of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, 32310, USA.
Lissa C AndersonNational High Magnetic Field Laboratory, Florida State University, 1800 East Paul Dirac Dr., Tallahassee, FL, 32310, USA.
David R BarnidgeDepartment of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA.
David L MurrayDepartment of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, 55905, USA.
Christopher L HendricksonDepartment of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, 32310, USA.
Alan G MarshallDepartment of Chemistry and Biochemistry, Florida State University, Tallahassee, FL, 32310, USA. marshall@magnet.fsu.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

With the rapid growth of therapeutic monoclonal antibodies (mAbs), stringent quality control is needed to ensure clinical safety and efficacy. Monoclonal antibody primary sequence and post-translational modifications (PTM) are conventionally analyzed with labor-intensive, bottom-up tandem mass spectrometry (MS/MS), which is limited by incomplete peptide sequence coverage and introduction of artifacts during the lengthy analysis procedure. Here, we describe top-down and middle-down approaches with the advantages of fast sample preparation with minimal artifacts, ultrahigh mass accuracy, and extensive residue cleavages by use of 21 tesla FT-ICR MS/MS. The ultrahigh mass accuracy yields an RMS error of 0.2-0.4 ppm for antibody light chain, heavy chain, heavy chain Fc/2, and Fd subunits. The corresponding sequence coverages are 81%, 38%, 72%, and 65% with MS/MS RMS error ~4 ppm. Extension to a monoclonal antibody in human serum as a monoclonal gammopathy model yielded 53% sequence coverage from two nano-LC MS/MS runs. A blind analysis of five therapeutic monoclonal antibodies at clinically relevant concentrations in human serum resulted in correct identification of all five antibodies. Nano-LC 21 T FT-ICR MS/MS provides nonpareil mass resolution, mass accuracy, and sequence coverage for mAbs, and sets a benchmark for MS/MS analysis of multiple mAbs in serum. This is the first time that extensive cleavages for both variable and constant regions have been achieved for mAbs in a human serum background. Graphical Abstract ᅟ.

Indexed as

AdalimumabAmino Acid SequenceAntibodies, MonoclonalFourier AnalysisHumansParaproteinemiasProtein Processing, Post-TranslationalSoftwareSpectrometry, Mass, Electrospray IonizationTandem Mass SpectrometryAdalimumabAntibodies, MonoclonalCIDCollision-induced dissociationElectron transfer dissociationElectrosprayETDFourier transformFTMSIon cyclotron resonanceIsotypeMiddle-downMS/MSMultiple myelomaVariable region

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.