Evidence map›Paper›PMID 28239554›Full record

ArticlePhotoacoustics2017

The development and characterization of a novel yet simple 3D printed tool to facilitate phantom imaging of photoacoustic contrast agents.

Santiago J Arconada-Alvarez, Jeanne E Lemaster, Junxin Wang, Jesse V Jokerst

Abstract read
In one paragraph

Article in Photoacoustics, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers.

0numbers the graph read from it
0cells of the map it votes in
18citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

18 citing papers in PubMed.

  1. Article
  2. Comparisons of 3D printed materials for biomedical imaging applications.Science and technology of advanced materials · 2023
    Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Review
  8. Article
  9. Article
  10. Stem Cell Tracking with Nanoparticle-Based Ultrasound Contrast Agents.Methods in molecular biology (Clifton, N.J.) · 2020
    Article
  11. Article
  12. Copper Sulfide Nanodisks and Nanoprisms for Photoacoustic Ovarian Tumor Imaging.Particle & particle systems characterization : measurement and description of particle properties and behavior in powders and other disperse systems · 2019
    Article
  13. Review
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Santiago J Arconada-AlvarezDepartment of NanoEngineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92092, USA.
Jeanne E LemasterDepartment of NanoEngineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92092, USA.
Junxin WangDepartment of NanoEngineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92092, USA.
Jesse V JokerstDepartment of NanoEngineering, University of California San Diego, 9500 Gilman Drive, La Jolla, CA, 92092, USA.

Funding

Therapeutic Drug Monitoring with a Wearable Ultrasound-based SensorDP2HL137187 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI JOKERST, JESSE VINCENT · 2016 to 2019
$2.7M
A Therapeutic Tool for Ultrasound-Guided Stem Cell TherapyR00HL117048 · NHLBI · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI JOKERST, JESSE VINCENT · 2015 to 2017
$747k
Vevo LAZR Photoacoustic Imaging SystemS10OD021821 · OD · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI HALL, DAVID J · 2016 to 2016
$594k
A Therapeutic Tool for ULtrasound-Guided Stem Cell TherapyK99HL117048 · NHLBI · STANFORD UNIVERSITY · PI JOKERST, JESSE VINCENT · 2014 to 2015
$265k
NHLBI NIH HHS DP2 HL137187NHLBI NIH HHS K99 HL117048NHLBI NIH HHS R00 HL117048NIH HHS S10 OD021821
6 · The paper itself

Abstract

We report a new approach to preparing phantoms using 3D printing. This device supports plastic tubing containing the contrast agent and is immersed in a solution with absorption or scattering properties that mimic tissue. Up to 12 tubing samples could be placed in the device with sample-to-sample spacing as low as 0.3 mm and at a constant distance from the transducer (±0.16 mm), which is critical in validating photoacoustic contrast agents. We also studied different types of tubing and found that tubing with a larger outside diameter has more inherent signal. Both 40% India Ink and lipids in the immersion media modulated the signal. Finally, we created a depth phantom and found that signal decayed following a linear relationship (R

Indexed as

3D printingOptoacoustic imagingPhantomPhotoacoustic imaging

Identifiers

PMID28239554
PMCPMC5314822

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.