ArticleSurgical endoscopy2017
The SmartOR: a distributed sensor network to improve operating room efficiency.
Article in Surgical endoscopy, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed.
- Improving operating room turnover efficiency with a real-time workflow coordination software in adult degenerative spine surgery.Journal of spine surgery (Hong Kong) · 2026Article
- Decoding the OR Black Box and Similar Technologies and Considerations in Otolaryngologic Surgery.Laryngoscope investigative otolaryngology · 2026Review
- Measuring provider-level differences in perioperative workflow using computer vision-based artificial intelligence.BMJ health & care informatics · 2025Article
- The Application of Human Factors Engineering to Reduce Operating Room Turnover in Robotic Surgery.World journal of surgery · 2022Article
- Artificial intelligence and anesthesia: a narrative review.Annals of translational medicine · 2022Review
- Modeling and Implementation of TEG-Based Energy Harvesting System for Steam Sterilization Surveillance Sensor Node.Sensors (Basel, Switzerland) · 2020Article
- A Systems Approach to Assess Transport and Diffusion of Hazardous Airborne Particles in a Large Surgical Suite: Potential Impacts on Viral Airborne Transmission.International journal of environmental research and public health · 2020Article
- On Providing Multi-Level Quality of Service for Operating Rooms of the Future.Sensors (Basel, Switzerland) · 2019Article
- A Continuum of Interfaces to Engage Surgical Staff in Efficient Collaboration.Journal of medical systems · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
Abstract
backgroundDespite the significant expense of OR time, best practice achieves only 70% efficiency. Compounding this problem is a lack of real-time data. Most current OR utilization programs require manual data entry. Automated systems require installation and maintenance of expensive tracking hardware throughout the institution. This study developed an inexpensive, automated OR utilization system and analyzed data from multiple operating rooms. STUDY
designOR activity was deconstructed into four room states. A sensor network was then developed to automatically capture these states using only three sensors, a local wireless network, and a data capture computer. Two systems were then installed into two ORs, recordings captured 24/7. The SmartOR recorded the following events: any room activity, patient entry/exit time, anesthesia time, laparoscopy time, room turnover time, and time of preoperative patient identification by the surgeon.
resultsFrom November 2014 to December 2015, data on 1003 cases were collected. The mean turnover time was 36 min, and 38% of cases met the institutional goal of ≤30 min. Data analysis also identified outlier cases (>1 SD from mean) in the domains of time from patient entry into the OR to intubation (11% of cases) and time from extubation to patient exiting the OR (11% of cases). Time from surgeon identification of patient to scheduled procedure start time was 11 min (institution bylaws require 20 min before scheduled start time), yet OR teams required 22 min on average to bring a patient into the room after surgeon identification.
conclusionThe SmartOR automatically and reliably captures data on OR room state and, in real time, identifies outlier cases that may be examined closer to improve efficiency. As no manual entry is required, the data are indisputable and allow OR teams to maintain a patient-centric focus.
Indexed as
Identifiers
28236014What OpenQuestion holds
Registered trials