ArticleEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2017
Application of a computer-assisted flexible endoscope system for transoral surgery of the hypopharynx and upper esophagus.
Article in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed, 17 citations in OpenAlex.
- Flexible transoral robotic surgery: the Italian experience.Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale · 2021Article
- Hypopharyngeal applications of a new flexible robotic system in otolaryngology.Journal of robotic surgery · 2018Article
- Robotics in otorhinolaryngology - head and neck surgery.Annals of the Royal College of Surgeons of England · 2018Review
- [Robotic Surgery - Who is The Boss?]Laryngo- rhino- otologie · 2018Review
- Robotic Surgery Techniques to Improve Traditional Laparoscopy.JSLS : Journal of the Society of Laparoendoscopic SurgeonsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Zenker's diverticulum is a common pathology in the transition zone of the posterior hypopharynx and esophagus. Surgical treatment is routinely performed by ENT and general surgeons. Besides the traditional open transcervical diverticulectomy, the introduction of transoral rigid treatment led to a paradigm change and is now the preferred treatment option for patients who are fit for general anesthesia. The implementation of interventional flexible endoscopy has opened another new micro-invasive approach for patients with high morbidity. Here, we present the potential utilization of a flexible, single port, robot-assisted, and physician-controlled endoscope system to facilitate transoral surgical access to the hypopharynx and upper esophagus. Transoral surgery of the hypopharynx and upper esophagus was performed in human cadavers (n = 5) using the Flex System (Medrobotics, Raynham, USA). Anatomical landmarks were identified, and posterior cricothyroid myotomy was performed with compatible flexible instruments in all cases. The approach to the hypopharynx and upper esophagus using the Flex system is feasible in a cadaveric model. Myotomy with a flexible tool and needle knife (from the perspective of treatment of Zenker´s diverticulum) was successful in all cases. Visualization of the surgical site with the system's HD camera is suitable and the flexible instruments meet the special needs of a micro-invasive transoral approach. Zenker´s diverticulum can be potentially treated with a transoral minimally invasive approach using a computer-assisted flexible endoscope system. This setup could be of advantage in patients with reduced mobility of the cervical spine to prevent open transcervical surgery. In our study, the Flex system enabled advanced visualization of the surgical site and extended intervention options, compared to standard flexible endoscopic treatment. However, general anesthesia is mandatory for the presented approach. Application in live patients with actual pathologies of the hypopharynx and upper esophagus will have to prove suitability for the treatment of Zenker's diverticulum. Further development of the system could include improved instrumentation and an adoption by other disciplines with challenging anatomy such as colorectal surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.