Evidence map›Paper›PMID 28234810›Full record

Trial reportPediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies2017

Seizure Detection by Critical Care Providers Using Amplitude-Integrated Electroencephalography and Color Density Spectral Array in Pediatric Cardiac Arrest Patients.

Geneviève Du Pont-Thibodeau, Sarah M Sanchez, Abbas F Jawad, Vinay M Nadkarni, Robert A Berg, Nicholas S Abend, Alexis A Topjian

Open access · greenAbstract readClinical TrialComparative Study
In one paragraph

Trial report in Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed, 1 pooled it
2.5field-weighted citation impact, top 11% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.

  1. Pooled it
  2. Review
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Observational
  13. Article
  14. Review
  15. Article
  16. Article
  17. Electroencephalography in epilepsy: look for what could be beyond the visual inspection.Neurological sciences : official journal of the Italian Neurological Society and of the Italian Society of Clinical Neurophysiology · 2019
    Review
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Geneviève Du Pont-Thibodeau1Department of Anesthesiology and Critical Care Medicine, The Children's Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA. 2Department of Pediatrics, The Children's Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA. 3Departments of Neurology and Pediatrics, The Children's Hospital of Philadelphia, University of Pennsylvania Perelman School of Medicine, Philadelphia, PA.
Sarah M Sanchez
Abbas F Jawad
Vinay M Nadkarni
Robert A Berg
Nicholas S Abend
Alexis A Topjian
Children's Hospital of Philadelphia · USPhiladelphia University · USUniversity of Pennsylvania · US

Funding

Non-convulsive seizures in critically ill children:physiology and outcomeK23NS076550 · NINDS · CHILDREN'S HOSP OF PHILADELPHIA · PI ABEND, NICHOLAS SCOTT · 2011 to 2015
$877k
Prompt Diagnosis and Treatment of Subclinical Seizures After Cardiac ArrestK23NS075363 · NINDS · CHILDREN'S HOSP OF PHILADELPHIA · PI TOPJIAN, ALEXIS A. · 2012 to 2016
$874k
NINDS NIH HHS K23 NS075363NINDS NIH HHS K23 NS076550
6 · The paper itself

Abstract

objectivesDetermine the accuracy and confidence of critical care medicine providers to identify seizures using amplitude-integrated electroencephalography versus amplitude-integrated electroencephalography combined with color density spectral array electroencephalography (aEEG + CDSA).

designTutorial and questionnaire.

settingPICU. SUBJECTS: Pediatric critical care providers (attendings, fellows, and nurses).

interventionsA standardized powerpoint tutorial on amplitude-integrated electroencephalography and color density spectral array followed by classification of 100 amplitude-integrated electroencephalography images and 100 amplitude-integrated electroencephalography combined with color density spectral array as displaying seizures or not displaying seizures. MEASUREMENTS AND MAIN

resultsElectroencephalography tracings were obtained from children monitored with continuous electroencephalography after cardiac arrest. The gold standard for seizure identification was continuous electroencephalography interpretation by a pediatric electroencephalographer. The same electroencephalography tracings were used to generate images containing only amplitude-integrated electroencephalography or aEEG + CDSA. Twenty-three critical care medicine providers underwent a 30-minute tutorial on amplitude-integrated electroencephalography and color density spectral array interpretation. They were then asked to determine if there were seizures on 100 amplitude-integrated electroencephalography images and 100 aEEG + CDSA. Amplitude-integrated electroencephalography seizure detection sensitivity was 77% (95% CI, 73%-80%), specificity of 65% (95% CI, 62%-67%), negative predictive value of 88% (95% CI, 86%-90%), and positive predictive value of 46% (95% CI, 43%-49%). For aEEG + CDSA, sensitivity was 77% (95% CI, 74%-81%), specificity of 68% (95% CI, 66%-71%), negative predictive value of 89% (95% CI, 87%-90%), and positive predictive value of 49% (95% CI, 46%-52%). Sensitivity for status epilepticus detection was 77% (95% CI, 71%-82%) with amplitude-integrated electroencephalography and 75% (95% CI, 69%-81%) with aEEG + CDSA. The addition of color density spectral array to amplitude-integrated electroencephalography did not improve seizure detection. However, 87% of critical care medicine providers qualitatively felt that combining both modalities increased their ability to detect seizures.

conclusionsAmplitude-integrated electroencephalography and aEEG + CDSA offer reasonable sensitivity and negative predictive value for seizure detection by critical care medicine providers. aEEG + CDSA did not improve seizure detection over amplitude-integrated electroencephalography alone although critical care medicine providers felt more confident using both tools combined. Amplitude-integrated electroencephalography and color density spectral array require further evaluation as a tool for screening for seizures and should only be used in conjunction with professional continuous electroencephalography review.

Indexed as

Clinical CompetenceAdolescentAttitude of Health PersonnelChildChild, PreschoolCritical CareElectroencephalographyHeart ArrestHumansInfantInfant, NewbornSeizuresSensitivity and Specificity

Identifiers

PMID28234810
PMCPMC5380542
OpenAlexW2591367492

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.