ArticleJournal of clinical monitoring and computing2018
Linshom thermodynamic sensor is a reliable alternative to capnography for monitoring respiratory rate.
Article in Journal of clinical monitoring and computing, 2018. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Novel device for monitoring respiratory rate during endoscopy-A thermodynamic sensor.World journal of gastrointestinal pharmacology and therapeutics · 2019Article
- A call to alarms: Current state and future directions in the battle against alarm fatigue.Journal of electrocardiologyReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Monitoring ventilation accurately is a technically challenging, yet indispensable aspect of patient care in the intra- and post-procedural settings. A new prototypical device known as the Linshom Respiratory Monitoring Device (LRMD) has been recently designed to non-invasively, inexpensively, and portably measure respiratory rate. The purpose of this study was to measure the accuracy and variability of LRMD measurements of respiratory rate relative to the measurement of capnography. In this prospective study, participants were enrolled and individually fitted with a face mask monitored by the LRMD and capnography. With a baseline oxygen flow rate and digital metronome to pace their respiratory rate, the participants were instructed to breathe at 10 breaths per minute (bpm) for 3 min, 20 bpm for 3 min, 30 bpm for 3 min, 0 bpm for 30 s, and resume regular breathing for 30 s. Both sensors were connected to a computer for continuous temperature and carbon dioxide waveform recordings. The data were then retrospectively analyzed. Twenty-six healthy volunteers, mean (range) age 27.8 (23-37) and mean (range) BMI 23.1 (18.8-29.2) kg/m
Indexed as
Identifiers
28229352What OpenQuestion holds
Registered trials