Evidence map›Paper›PMID 28222206›Full record

ArticleJournal of applied biomaterials & functional materials2017

Titanium-hydroxyapatite composites sintered at low temperature for tissue engineering: in vitro cell support and biocompatibility.

Romina Comín, Mariana P Cid, Luciano Grinschpun, Carlos Oldani, Nancy A Salvatierra

Open access · hybridAbstract read
In one paragraph

Article in Journal of applied biomaterials & functional materials, 2017. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
0.8field-weighted citation impact, top 30% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 26 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Surface properties and bioactivity of TiORoyal Society open science · 2019
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Romina ComínIIBYT-UNC-CONICET, Department of Chemistry, School of Exact, Physics and Natural Sciences, National University of Córdoba, Córdoba - Argentina.
Mariana P CidIIBYT-UNC-CONICET, Department of Chemistry, School of Exact, Physics and Natural Sciences, National University of Córdoba, Córdoba - Argentina.
Luciano GrinschpunDepartment of Materials, School of Exact, Physics and Natural Sciences, National University of Córdoba, Córdoba - Argentina.
Carlos OldaniDepartment of Materials, School of Exact, Physics and Natural Sciences, National University of Córdoba, Córdoba - Argentina.
Nancy A SalvatierraIIBYT-UNC-CONICET, Department of Chemistry, School of Exact, Physics and Natural Sciences, National University of Córdoba, Córdoba - Argentina.
Universidad Nacional de Córdoba · ARConsejo Nacional de Investigaciones Científicas y Técnicas · AR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIn clinical orthopedics, a critical problem is the bone tissue loss produced by a disease or injury. The use of composites from titanium and hydroxyapatite for biomedical applications has increased due to the resulting advantageous combination of hydroxyapatite bioactivity and favorable mechanical properties of titanium. Powder metallurgy is a simple and lower-cost method that uses powder from titanium and hydroxyapatite to obtain composites having hydroxyapatite phases in a metallic matrix. However, this method has certain limitations arising from thermal decomposition of hydroxyapatite in the titanium-hydroxyapatite system above 800°C. We obtained a composite from titanium and bovine hydroxyapatite powders sintered at 800°C and evaluated its bioactivity and cytocompatibility according to the ISO 10993 standard.

methodsSurface analysis and bioactivity of the composite was evaluated by X-ray diffraction and SEM. MTT assay was carried out to assess cytotoxicity on Vero and NIH3T3 cells. Cell morphology and cell adhesion on the composite surface were analyzed using fluorescence and SEM.

resultsWe obtained a porous composite with hydroxyapatite particles well integrated in titanium matrix which presented excellent bioactivity. Our data did not reveal any toxicity of titanium-hydroxyapatite composite on Vero or NIH3T3 cells. Moreover, extracts from composite did not affect cell morphology or density. Finally, NIH3T3 cells were capable of adhering to and proliferating on the composite surface.

conclusionsThe composite obtained displayed promising biomedical applications through the simple method of powder metallurgy. Additionally, these findings provide an in vitro proof for adequate biocompatibility of titanium-hydroxyapatite composite sintered at 800°C.

Indexed as

Biocompatible MaterialsDurapatiteTissue EngineeringTitaniumAnimalsChlorocebus aethiopsMaterials TestingMiceNIH 3T3 CellsTemperatureVero CellsBiocompatible MaterialsDurapatiteTitanium

Identifiers

PMID28222206
PMCPMC6379773
OpenAlexW2590174886

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.